OPERATION PANEL QUICK REFERENCE
UP/DOWN: This key is
used to scroll through
display choices and
change values that can
be SET.
ENTER: This key is used to
store values that have been
changed, and to respond to
display commands.
SET: This key is used to
display and change
settable values, such as:
Local Time, Quiet Time
Start and End (QT Start
and QT End).
START/STOP: Works exactly like the
genset switch. If the genset switch has a
run light and flashes diagnostics, the EC-
30 run light will also be on when the
genset is running, flash during preheat,
and flash genset fault messages.
AUTO GEN: This key selects genset operating Mode:
MANUAL - Operator start/stop. No automatic.
AUTO ON - Automatic start/stop available.
QUIET ON - Automatic start/stop not available during quiet time,
Note: AUTO ON requires two keystrokes. First press AUTO GEN when
in MANUAL mode;
…is displayed. Next press
ENTER for AUTO ON mode.
Do not select AUTO ON mode before reading and understanding this
Instruction Sheet and without following its Safety Precautions!
Note: When operating Mode is not being displayed, pressing the AUTO GEN key will
take the display to its default: Local Time and Generator Mode.
ENTER
for auto