Installation manual

Page 7
Setting Up and Testing the Energy Command 30
Overview
This section describes how to Setup and Test the EC-
30. Before using the EC-30 for the first time check to
be sure that the unit is setup appropriately for the
system. The character < is used to indicate all default
values. Also see Figures #1-4.
Setting GEN TYPE and Safety Type Is
Required for Automatic Operation
The very first time the EC-30 is turned on (power
applied) an initial setup procedure begins. The EC-30
requires setup of both the GEN TYPE and Safe Type
prior to allowing automatic operation.
The genset type also sets the Service Interval for
service messages and critical automatic starting
parameters. The first service interval is 50 hours for all
models. See SETUP GENSET to change the genset
type after first power up.
Setting GEN TYPE
First enter the correct GEN TYPE. If no GEN TYPE
has been selected and the AUTO GEN switch is
pressed, the display will say:
GEN TYPES TABLE 1
GEN TYPE MODEL Service In
NONE< --- ---
QD 10/12 Quiet Diesel 250 hours
QD 6/8 Quiet Diesel 150 hours
QD 5.5 Quiet Diesel 150 hours
GAS/LP Marquis, Microlite,
Micro Quiet,
150 hours
GAS RV Camp Power 150 hours
The word NONE will be flashing. Use the UP/DOWN
key and the table above to select the correct genset
type. Press ENTER when the correct genset is
displayed. The next display will say:
Setting Safety Type
The Safety Input is described in detail in the Installation
section of this manual. The Safety Input must be
supplied from:
Ignition: Input is connected to the vehicle
ignition system (motor homes or van
conversions).
Brake: Brake light for all trailer, 5
th
wheel and
pickup camper installations, or air brake on
diesel motor homes.
Park: The park signal/neutral (transmission)
from motorized motor homes or van
conversions.
The displays for the choices are:
If setup of the SafeType is skipped, pressing the AUTO
GEN key will begin this procedure.
SETUP & INFO Displays
The SETUP & INFO displays are used to tailor the EC-
30 to the particular system and application. Refer to
Figure #1 for the various main displays that are
available. To access the SETUP & INFO displays use
the UP/DOWN key to navigate to the SETUP & INFO
display and press ENTER. (See Figure #2: Setup &
Info Displays) The UP/DOWN key now allows scrolling
through the various choices. To access a choice press
the ENTER key. Again the UP/DOWN key is used to
navigate through the available displays. Use the
ENTER To Exit display to continue through the
previous displays or:
Press the AUTO GEN key anytime to
return to the default display.
Safe Type
NONE
GEN TYPE
NONE
SafeType
NONE
Use the UP/DOWN
switch to select the
correct safety type.
Press ENTER when
correct type is displayed.
Safe Type
BRAKE
Safe Type
IGNITION
Safe Type
PARK