9-2013 3. Maintenance
3.9 Accessory Heater Kits
WARNING
Electrical connections must be made by a trained and experienced electrician. Improper
installation can lead to electrocution and damage to property. Automatic startup of the generator
set during installation can cause severe personal injury or death. Push the control switch Off and
disconnect the negative (–) cable from the battery to keep the generator set from starting.
An optional thermostatically controlled battery heater is available for more reliable starting in
ambient temperatures down to -20 °F (-28.8 °C). The heater wraps around the battery. The
heater cord is connected in the 120V junction box.
An optional thermostatically controlled oil and alternator heater assembly is also available for
more reliable generator starting at low ambient temperatures. The heater cord is connected in
the 120V junction box.
TABLE 11. HEATER KITS AND PARTS
Part Description Model/Part Number (included in product unless otherwise noted)
Heater Assembly (Spec A and 20GSBB-6714A
Canadian GSBB Spec B)
Heater Assembly (US GSBB 20GSBB-6714B, 20GSBC-6727B, 15GSBB-6720B
Spec B and Canadian GSBC
Spec B)
Harness, Interface (Spec A and A030B021
Canadian GSBB Spec B)
Harness, Interface (US GSBB A041U952
Spec B and Canadian GSBC
Spec B)
Harness, Heater (Oil Heater) A030B021
(Spec A and Canadian GSBB
Spec B)
Harness, Heater (Alternator A030B021
Heater) (Spec A and Canadian
GSBB Spec B)
Harness, Heater (Alternator Accessory Only
Heater) (US GSBB Spec B and
Canadian GSBC Spec B)
Battery Heater Kit Accessory Only
Breather Shroud Accessory Only
3.10 Maintenance Record
Record all periodic and unscheduled maintenance and service. See the Periodic Maintenance
Schedule for a list of scheduled maintenance frequency.