Specifications

17
MAINTAINING THE BATTERY AND
BATTERY CONNECTIONS
WARNING
Arcing at battery terminals or in
light switches or other equipment, and flames or
sparks, can ignite battery gas causing severe
personal injury.
Ventilate battery area before working on or near
battery—Wear safety glasses—Do not smoke—
Switch trouble light ON or OFF away from bat-
tery—Stop genset and disconnect charger be-
fore disconnecting battery cables—Disconnect
negative () cable first and reconnect last.
Refer to Table 3 for scheduled battery maintenance,
and follow the battery manufacturers instructions.
Have the battery charging system serviced if DC
system voltage is consistently low or high. Always:
1. Keep the battery case and terminals clean and
dry and the terminals tight.
2. Remove battery cables with a battery terminal
puller.
3. Make sure which terminal is positive (+) and
which is negative () before making battery
connections, always removing the negative ()
cable first and reconnecting it last to reduce
arcing.
REPLACING THE AIR FILTER ELEMENT
Refer to Table 3 for scheduled air filter element re-
placement. In dusty environments the filter element
should be inspected and changed more frequently.
To change the filter element (Figure 7), remove the
outer and inner cover and reassemble with a new air
filter element. Turn the inner cover wingnut three to
four clicks past seating. Make sure the outer cover is
seated before tightening its wingnut. Check for
noise when the genset is running, and retighten
if necessary.
OUTER COVER INNER COVER FILTER ELEMENT SPACER SEAL HOUSING
FIGURE 7. REPLACING THE AIR FILTER ELEMENT