Installation manual

2. Introduction 4-2010
60 Hz 50 Hz
Propane Vapor Natural Gas Propane Vapor Natural Gas
Operating Temperature Range
Below 20 °F (-7 °C) Additional oil heater recommended for starting. Factory-installed model available.
Below 0 °F (-18 °C) Additional accessory breather heater required to avoid possible engine damage.
See warranty statement.
Below -10 °F (-23 °C) Additional accessory battery blanket recommended for starting.
Below -20 °F (-29 °C) Not warranted. See warranty statement.
TABLE 3. GENERATOR SET SPECIFICATIONS TABLE
60 Hz 50 Hz
Propane Vapor Natural Gas Propane Vapor Natural Gas
Dimensions
Weight (With Oil) 540 lbs (245 kg)
Size (L x W x H) 48 x 43 x 34.6 in (1219 x 864 x 880 mm)
Noise 62 dB(A) at 23 ft (7 m) at normal load. (Normal load is equal to the typical
household consumption of 3 KW.)
TABLE 4. FUEL SPECIFICATIONS TABLE
60 Hz 50 Hz
Propane Vapor Natural Gas Propane Vapor Natural Gas
Fueling
1/2 Load 132,500 Btu/Hr 135,000 Btu/Hr 122,000 Btu/Hr 114,000 Btu/Hr
35 ft
3
/Hr 135 ft
3
/Hr 48 ft
3
/Hr 110 ft
3
/Hr
Full Load 275,000 Btu/Hr 240,000 Btu/Hr 229,000 Btu/Hr 213,000 Btu/Hr
110 ft
3
/Hr 240 ft
3
/Hr 90 ft
3
/Hr 205 ft
3
/Hr
Fuel Pressure 7-11 inches WC 5-11 inches WC 7-11 inches WC 5-11 inches WC
Tank Size Contact your local gas company to verify the tank size required for your application.
TABLE 5. ENGINE SPECIFICATIONS TABLE
60 Hz 50 Hz
Propane Vapor Natural Gas Propane Vapor Natural Gas
Engine 2 Cylinder-V Twin, OHV, Air-Cooled, 4-Stroke, Spark Ignited, 3600 RPM
Displacement 60.59 in
3
(993 cc)
Spark Plug Gap .020 inch (.51 mm)
Spark Plug Torque 15 ft-lb (20 N-m)
Intake and Exhaust Cold Valve 0.004-0.006 inch (0.10 - 0.15 mm)
Lash
(Measure at 0.25" (6.35mm)
past top dead center)
6 A029V088 (Issue 2)