Owner`s manual

59 60
RV QG 5500/7000 EFI
• Electronic fuel injection.
- Improved hot and cold starts
- Automatic altitude compensation
- No carburetor gumming after storage
• Runs one or two 13500 BTU air conditioners with power to spare.
• Electronic governor.
• Fully integrated design makes it the quietest in its class.
- Enclosed muffl er
- Low vibration levels
- Self diagnostic capability to simplify troubleshooting
- Digital voltage regulation for stability as appliance loads change
• Gasoline or LP-fueled.
Dimensions: (L x W x H in inches)
All models 33.6 x 22.2 x 16.7
Engine Detail:
4-cycle, OHV, 90-degree V-Twin.
Power Capabilities: (at 100ºF and 500’ altitude)
RV QG 5500/5500 EFI LP: Starts one 13500 BTU air conditioner with 3000-
watt baseload. Or, two 13500 BTU air conditioners with 1300-watt baseload.
RV QG 7000/6500 EFI LP: Starts two 13500 BTU air conditioners with
3000-watt baseload.
RV QG 5500/7000/6500 EFI Specifi cations
Model 5500 EFI 5500 LP 7000 EFI 6500 LP
Watts 5500 5500 7000 6500
RPM
2400 2400 2880 2880
Volts 120 120 120 120
Hertz 60 60 60 60
Amps 45.8 45.8 58.3 54.2
Weight (lb) 279 279 290 294
Avg. Fuel Consumption (gal/hr) (gal/hr) (lb/hr) (gal/hr) (gal/hr) (lb/hr)
No Load 0.3 0.4 1.7 0.4 0.5 2.1
Half Load 0.6 0.8 3.4 0.7 0.8 3.4
Full Load 0.9 1.1 4.7 1.1 1.2 5.1
Sound Level dB(A)
Half Load* 64 64 64 64
Engine Horsepower 12.9 10.7 12.3 11.6
*Typical RV installation. All readings at 10 ft. (3m).
RV QG 7000 EFI
RV QG 5500, 7000/6500 EFI
RV QG 5500 EFI