Service Manual

ISB, ISBe and QSB (Common Rail [...] Accessory Drive
Section 9 - Drive Units - Group 09 Page 9-1
To buy Cummins Parts and Service Manuals, Training Guides, or Tools go to our website at https://store.cummins.com
Accessory Drive (009-001)
Preparatory Steps
WARNING
Batteries can emit explosive gases. To reduce the
possibility of personal injury, always ventilate the
compartment before servicing the batteries. To
reduce the possibility of arcing, remove the negative
(-) battery cable first and attach the negative (-)
battery cable last.
Disconnect the batteries.
Remove the driven accessory. Refer to the OEM
instructions.
NOTE: Typically the driven accessory is a hydraulic
pump. Refer to Procedure Procedure 009-016 for general
removal instructions.
Remove
Remove the two capscrews securing the accessory drive
to the rear gear housing.
Remove the accessory drive and gasket.
Clean and Inspect for Reuse
Remove any residual gasket material from the mounting
surfaces of the accessory drive, driven accessory/
hydraulic pump, and, if equipped, the cover plate surface.