Turbocharger Compressor Outlet
Connection (010-132)
General Information
This procedure includes instructions on removal, cleaning/
inspection, and installation of the turbocharger
compressor outlet connection. There are many different
styles of outlet connection on the ISB/QSB/ISB
e
series
engines, and the pictures contained in this procedure may
not exactly represent the actual hardware on the engine
being serviced. However, the procedures for removal,
cleaning/inspection, and installation of each different
turbocharger compressor outlet connection are identical.
Preparatory Steps
WARNING
Batteries can emit explosive gases. To reduce the
possibility of personal injury, always ventilate the
compartment before servicing the batteries. To
reduce the possibility of arcing, remove the negative
(-) battery cable first and attach the negative (-)
battery cable last.
Disconnect the batteries.
Clean the outside of the turbocharger compressor outlet
connection with a clean cloth, making sure to remove any
dirt which could fall into the intake when the charge air
piping is removed.
Disconnect the charge air piping and connections from the
turbocharger compressor outlet connection. Refer to
Procedure Procedure 010-019