Service Manual

Alternator Bracket ISB, ISBe and QSB (Common Rail [...]
Page 13-14 Section 13 - Electrical Equipment - Group 13
To buy Cummins Parts and Service Manuals, Training Guides, or Tools go to our website at https://store.cummins.com
Remove the drive belt. Refer to Procedure 008-002.
Remove the alternator. Refer to Procedure 013-001.
Marine Applications
WARNING
Batteries can emit explosive gases. To reduce the
possibility of personal injury, always ventilate the
compartment before servicing the batteries. To
reduce the possibility of arcing, remove the negative
(-) battery cable first and attach the negative (-)
battery cable last.
Disconnect the battery. Refer to Procedure 013-009.
Remove the belt guards. Refer to Procedure 008-001.
Remove the water pump (cooling fan) drive belt from the
alternator pulley. This can be done without removing the
sea water pump drive belt. Refer to Procedure 008-002.
Remove the alternator. Refer to Procedure 013-001.
Remove
Spool Mount
NOTE: On some applications, the alternator bracket and
water inlet are combined in the same bracket. Refer to
Procedure 008-082, where applicable.
Remove the upper alternator bracket mounting
capscrews.
Remove the lower alternator bracket mounting capscrews.
Remove the alternator bracket.
Hinge Mount:
Remove the upper alternator bracket mounting
capscrews.
Remove the lower alternator bracket mounting capscrews.
Remove the alternator bracket.