Service Manual

Crankcase Blowby, Measure ISB, ISBe and QSB (Common Rail [...]
Page 14-38 Section 14 - Engine Testing - Group 14
To buy Cummins Parts and Service Manuals, Training Guides, or Tools go to our website at https://store.cummins.com
For ISB CM2150 engines that have the crankcase
ventilation filter located at the rear of the engine, use the
following steps to connect the blowby measurement tools.
Disconnect the crankcase ventilation line from the
crankcase ventilation filter housing. Plug or cap the
crankcase ventilation filter housing.
Connect the appropriate blowby service tool to the
crankcase ventilation line exiting the flywheel housing.
Connect a water manometer, pressure gauge, or
transducer to the blowby service tool.
For ISC and ISL CM2150 and QSL CM2250 engines, use
the following steps to connect the blowby measurement
tools.
Remove the oil fill cap from the rocker lever cover.
Install an oil fill adapter, Part Number 3990099.
Connect the appropriate blowby service tool to the
outlet of the oil fill adapter. Connect a water
manometer, pressure gauge, or transducer to the
blowby service tool.