Lubricating Oil Sludge in the Crankcase Excessive
Cause Correction
STEP 1
Bulk oil supply is contaminated
.............
Check the bulk oil supply. Drain the oil and replace
with noncontaminated oil. Replace the oil filter(s).
Refer to Section 5. Use the oil recommended in
Section V.
OK
Go To Next Step
STEP 2
Coolant temperature is below specification
.............
Refer to the Coolant Temperature Below Normal
symptom tree.
OK
Go To Next Step
STEP 3
Crankcase ventilation system is plugged
.............
Check and clean the crankcase breather and vent
tube. Refer to Section 3.
OK
Go To Next Step
STEP 4
Fuel grade is not correct for the application or the
fuel quality is poor
.............
Operate the engine from a tank of high-quality fuel.
Refer to Fuel Recommendations and
Specifications in Section V.
OK
Go To Next Step
STEP 5
Lubricating oil does not meet specifications for
operating conditions
.............
Change the oil and filters. Refer to Section 5. Use
the oil recommended in Section V.
OK
Go To Next Step
STEP 6
Contact a Cummins® Authorized Repair Facility