Specifications
23
Ventilation Requirements
• This appliance is not connected to a combustion products evacuation device. It should be installed and 
connected in accordance with current installation regulations. Particular attention should be given to the 
relevant requirements regarding ventilation.
• The appliance should be installed in a room or space with an air supply in accordance with the latest edition of 
BS5440-2.
• For rooms with a volume of less than 5m
3
 — permanent ventilation of 100cm
2
 free area will be required.
• For rooms with a volume of between 5m
3
 and 10m
3
 a permanent ventilation of 50cm
2
 free area will be required 
unless the room has a door which opens directly to the outside air in which case no permanent ventilation is 
required.
• For rooms with a volume greater than 10m
3
 — no permanent ventilation is required.
Installation and Service Regulations
Gas Installation
• Regardless of room size, all rooms containing the appliance must have direct access to the outside air 
via a window that opens or equivalent.
• Where there are other fuel burning appliances in the same room, the latest edition of BS 5440-2 should 
be consulted to determine the correct amount of free area ventilation requirements.
This cooker uses and is ready to use NATURAL GAS only and cannot be used with any other gas without 
modication. This appliance is manufactured for conversion to LPG after tting new injectors, new supply 
hose and making adjustments. Refer to “replacement of burner injectors” section for details.
This appliance must be installed and serviced only by a suitably qualied and Gas Safe Registered 
engineer, and in accordance with the current editions of the following standards and regulations or other 
locally applicable regulations:
• Gas Safety (Installation and Use) Regulations
• Building Regulations
• British Standards (BS 5440, BS 6172 and BS 6891)
• Regulations for Electrical Installation (BS 7671, (Latest Edition))