Gas Connection
The installation of the cooker to Natural Gas or LP Gas must be carried out by a Gas Safe registered engineer. 
Installers must take account of the provisions of the relevant British Standards Code of Practice, the Gas Safety 
Regulations and the Building Regulations.
Installation Relevant to Natural Gas
Installation to Natural Gas must conform to the Industry Standards, etc. The supply pressure for Natural Gas is 
20 mbar.
Installation Relevant to Liquid Petroleum Gas (LPG)
This appliance must only be connected to LPG after an LPG 
conversion kit has been tted. The installation must conform 
to the relevant British Standards.
It is recommended that the gas connection to the cooker is installed with a exible connecting tube 
made to BS669.
• Only a suitably qualied and Gas Safe Registered 
Engineer may convert the appliance to a dierent 
gas type.
• When using Butane gas a supply pressure of 28 -30 
mbar is required.
• When using Propane gas a supply pressure of 37 
mbar is required.
• Flexible hoses can be used where the sited 
ambient temperature of the hose does not exceed 
70°C. These hoses must be manufactured in 
accordance with BS669 part 1 and be of the correct 
construction for the type of gas being used.
• Gas hoses designed for natural gas MUST NOT be 
used for supplying LPG gas (LPG gas hoses can be 
identied by a either a red band or stripe on the 
rubber outer coating of the hose).
• The hose should not be crushed or trapped or be 
in contact with sharp or abrasive edges. It should 
also not be subjected to corrosion by acidic 
cleansing agents.
* All images are for indication only; please refer to your individual unit for actual item.
CFSGWH_SV12_IB_120607_Annie.indd 24 12年6月7日 下午7:15