Specifications
27
Remove the injector with a 7 mm spanner and replace the 
injector with the ones from the spare set, with corresponding 
diameters suitable to the type of gas that is going to be used, 
according to the information chart (which is also supplied in the 
gas conversion kit).
To Replace the Oven/Grill Injectors
Removal of the Grill Burner Injector
The grill injector can be accessed by removing the single screw 
on the tip of the burner (as shown). Remove the screw and pull 
the grill burner towards the front of the cooker, the injector will 
be revealed on the rear surface of the cavity.
Screw
Removal of the Oven Burner Injector
The Oven Burner Injector is not accessible; to change or service this part, please contact a qualied engineer. 
Adjusting the Reduced Flame Position
For the oven burner, operate the oven burner at minimum position for 5 minutes, then open and close the oven 
door 2-3 times to check the burner’s ame stability.
Reduced ame position adjustment is not required for grill burners.
The position of the adjustment screw must be loosened (turn 
anti-clockwise) for conversion from LPG to NG. For conversion 
from NG to LPG, the same screw must be tightened (turn 
clockwise). Make sure that the appliance is unplugged from 
the electric mains and the gas supply is open.
Adjustment 
Screw
Thermostatic oven valve
* All images are for indication only; please refer to your individual unit for actual item.
CFSGWH_SV12_IB_120607_Annie.indd 27 12年6月7日 下午7:15