Specifications
10
Curtis 1310 Manual, Rev. B
Table 5 Connector J4: Specialty I/O
RELATED VCL
PIN NAME DESCRIPTION
FUNCTIONS REFERENCES
1 Encoder 1A Pulse count input, or encoder Setup_Encoder ENC1
channel A. Get_Enc_Count ENC1_Count
Get_Enc_Dir ENC1_Dir
Get_Enc_Vel ENC1_Vel
Get_Enc_Error ENC_Error
SW_23
2 Encoder 1B Encoder channel B. SW_24
3 Encoder 2A Pulse count input or encoder Setup_Encoder ENC2
channel B. Get_Enc_Count ENC2_Count
Get_Enc_Dir ENC2_Dir
Get_Enc_Vel ENC2_Vel
Get_Enc_Error ENC_Error
SW_25
4 Encoder 2B Encoder channel B. SW_26
5 Pot High The high voltage reference Get_Pot POT_High
for the four potentiometer inputs. Get_ADC ADC1
ADC_Output
6 Wiper 1 A generic 0–5V input which can Get_Pot POT1_Output
also be set up as a potentiometer Setup_Pot ADC2_Output
wiper input. Setup_Pot_Filtered
Get_ADC
7 Wiper 2 A generic 0–5V input which can Get_Pot POT2_Output
also be set up as a potentiometer Setup_Pot ADC3_Output
wiper input. Setup_Pot_Filtered
Get_ADC
8 Wiper 3 A generic 0–5V input which can Get_Pot POT3_Output
also be set up as a potentiometer Setup_Pot ADC4_Output
wiper input. Setup_Pot_Filtered
Get_ADC
9 Wiper 4 A generic 0–5V input which can Get_Pot POT4_Output
also be set up as a potentiometer Setup_Pot ADC5_Output
wiper input. Setup_Pot_Filtered
Get_ADC
10 Pot Low The low voltage reference Get_Pot POT_Low
for the four potentiometer inputs. Get_ADC ADC6_Output
11 Analog Output 1 0–10V analog output. Put_DAC DAC1
Automate_DAC
12 Analog Output 2 0–10V analog output. Put_DAC DAC2
Automate_DAC
13 Not used
14 PWR_UP B+ input that can be used to Get_ADC ADC7_Output
to power up the 1310 controller.
15 +5V +5V to power sensors. Can supply Get_ADC ADC11_Output
up to 200 mA. The output current
is monitored at ADC11.
16 GND Ground reference.
2 — INSTALLATION & WIRING: Connector J4