Specifications

18
Curtis 1310 Manual, Rev. B
3 — PROGRAMMABLE PARAMETERS
3
PROGRAMMABLE PARAMETERS
The Curtis 1310 Vehicle System Controller is designed to be a universal con-
trol block, and therefore has only a few “ready-made” standard parameters that
can be adjusted via the 1311 handheld programmer. Many custom parameters
and menus can be added to meet the needs of the application, using the VCL
programming language. Refer to Section 5 of the VCL Programmers Guide for
detailed information on setting up parameter lists and menus that can be read by
the Curtis 1311 handheld programmer or Curtis 1314 PC-based programmer.
For programmer operation, see Appendix C.
PROGRAMMING MENUS
The standard programmable parameters are grouped these two menus:
BATTERY MENU
—Nominal Voltage
—Reset Volts Per Cell
—Full Volts Per Cell
—Empty Volts Per Cell
—Discharge Time
—BDI Reset Percent
CAN INTERFACE MENU
—Master ID
—Slave ID
—Baud Rate
—Heartbeat Rate
—PDO Timeout Period
—Emergency Message Rate
—Suppress CANopen Init
Individual parameters are presented as follows in the menu charts:
Parameter name Allowable range Description of the parameter’s
as it appears in the in the function and, where applicable,
programmer display programmer’s units suggestions for setting it
Nominal Voltage 24–48 V Must be set to the system’s nominal battery voltage. This value is used in
Nominal_Voltage 1536–3072 determining the number of cells in the battery pack for the BDI parameters.
Parameter name Allowable range
in VCL in VCL units