Specifications

Curtis 1310 Manual, Rev. B
21
1 6 F E B R U A R Y 2 0 0 8 D R A F T
4a
4a — MONITOR MENU
MONITOR MENU
Through its Monitor menu, the 1311 programmer provides access to many
internal variables that are continuously read and updated. This information
is helpful during diagnostics and troubleshooting, and also while adjusting
programmable parameters.
MONITOR MENU
—PWM Outputs
—Analog Outputs
—Analog Inputs
—Pot Inputs
—Switches
—CAN Status
Monitor Menu: PWM OUTPUTS
DISPLAY
VARIABLE RANGE DESCRIPTION
Channel # 0–32767 PWM output value (32767 = 100%) of one
PWM#_Output 0–32767 of the 16 PWM signals.
# = 1 through 16.
Monitor Menu: ANALOG OUTPUTS
DISPLAY
VARIABLE RANGE DESCRIPTION
Channel # 0–32767 Analog output value (32767 = 10 V) of one
DAC#_Output 0–32767 of the 2 DAC channels.
# = 1 or 2.
Monitor Menu: ANALOG INPUTS
DISPLAY
VARIABLE RANGE DESCRIPTION
KSI Filtered 0–100.0 V Filtered and calibrated value of the B+ / KSI
KSI_Filtered 0–10000 input signals. 1 volt = 100 counts.
KSI Raw 0–1023 Unfiltered (raw) value of the B+ / KSI input
KSI_Raw 0–1023 signals. ~1 volt = 9.5 counts (uncalibrated).
Channel # 0–1023 Analog input value (~1023 = 5 volts) of one
ADC#_Input 0–1023 of the 16 ADC channels.
# = 1 through 16.