MODEL 2100R & 2200R Engine Gages ! Read Instructions Carefully !
! Safety Instructions This instrument was manufactured and tested according to the applicable technical standards. It complies with all the safety regulations as shipped from the factory. Installation and startup must be performed by skilled personnel. Failure to install and operate the unit in accordance with these instructions may result in damage or injury. If safe operation of the instrument can no longer be ensured, stop and secure it against accidental operation.
TABLE OF CONTENTS 1. Safety Instructions 2. Model Encodement 3. Technical Specifications 3.1 Electrical 3.2 Mechanical 3.3 Environmental 4. Installation 5. Troubleshooting 6.
2.
! R = case (round) XX = voltage (DC voltages only) YYYY = sequential number code describes gage’s factory programming ZZ = artwork code (OO = Curtis) 4
! 3. TECHNICAL SPECIFICATIONS 3.1 Electrical Operating Voltage Model Series 2100R and 2200R are available in either 12VDC or 24VDC (negative ground systems only) Operating Voltages (Models 2111R, 2112R, 2113R and 2211R, 2212R, 2213R) Model Minimum Nominal Maximum 12V 9.0 12.0 16.0 24V 18.0 24.0 32.0 (Models 2114R and 2214R) Model Minimum Nominal 12V 8.0 12.0 24V 16.0 24.0 Maximum 18.0 36.0 Accuracy Maximum indicator error is less than ±3.
Operating Current ! Total system current is a function of the voltage, sender type, display mode, and the gage’s factory programming. Typical operating currents (not including the current to drive the sender) vary from 16-55 mA, for 12V models, depending on model number. For 24V models, typical operating currents (not including the current to drive the sender) vary from 18-45 mA, depending on model number.
Output signal trigger point (lower) First LED Second LED Output signal trigger point (upper) Ninth LED Tenth LED Output signal format—(upper and lower independently set) 0-5 V 5-0 V* LED flashing mode (lower) No flashing First LED flashes alone First LED or second flashes alone Both first & second flash out of phase* LED flashing mode (upper) No flashing Tenth LED flashes alone Both tenth & ninth flash in phase Both tenth & ninth flash out of phase* ! *indicates standard setting 7
Damping and Hysteresis Transducer power modulation (XPM) Used to reduce current in sender circuit ! Output signal format Outputs are capable of sinking or sourcing up to 1mA, maximum (50µA maximum is standard) The 5V-0 output signal format is fully compatible with the Curtis Model 1178 relay module. 3.2 Mechanical Terminals (Spade) Dimensions Weight Lens Material Case Material 6 ANSI/NEMA 0.25 inch male fast-ons Bezel diameter 58.8 mm, maximum Case diameter 51.5 mm, maximum Depth 45.
Bezel Material Hardware (Individually boxed units) Hardware (OEM bulk packed) Aluminum, black anodized U clamp (1) 4 mm lock washers (2) Female 1/4 inch fast-on connectors (up to 6) 4 mm knurled thumbnuts (2) U clamp (1) 4 mm lock washers (2) 4 mm hex nuts (2) ! 3.3 Environmental Temperature Operating Storage Shock -40C to +85C -50C to +90C Meets SAE J 1378 March 83. Amplitude 44-55g, half sine, 9-13 msec duration.
Vibration Meets SAE J 1378 March 83. Double amplitude of 1.53 mm with frequency sweep from 10-80-10 Hz (20 g max) at intervals of 1 minute. Humidity 95% RH (non-condensing) at +38C Water/dust immunity Face Rear IP63 IP50 Salt spray (fog) ASTM B 117-73 as per SAE J1810, section 4.7.1.
! 4.
Terminal Assignment for Model 2114R 1 2 3 4 5 6 Not Connected ** Battery + Ground Not Connected** Output signal (upper) Output signal (lower) ! Terminal Assignments for Models 2211R, 2212R, 2213R 1 2 3 4 5 6 Sender in Battery + Ground Hourmeter enable* Output signal (upper) Output signal (lower) 12
Terminal Assignments for Model 2214R 1 2 3 4 5 6 ! Not connected*** Battery + Ground Hourmeter enable*** Output signal (upper) Output signal (lower) * Options terminal can be factory programmed to function as hourmeter reset or sender low (for use with two wire senders) **Options terminal-can be factory programmed to measure a separate variable voltage supply. ***Options terminals-can be factory programmed to measure a separate variable voltage supply.
5. TROUBLESHOOTING The following checklist should help you to troubleshoot any problems with the instrument. Turning the instrument off and then on again after about 10 seconds may solve the problem in the simplest cases. Make sure to observe the safety instructions in Section 1. Problem No display Display is not accurate ! Possible Cause Voltage on Battery + terminal insufficient Check sender installation.
6. MAINTENANCE Curtis 2100R & 2200R Series Engine Gages are not serviceable in the field. Units returned to the factory within the warranty period will be replaced without charge.
Guarantee - These Curtis Instruments’ products are guaranteed against defects in workmanship and material for a period of three years, or as defined in the individual product literature, from date of shipment from our factory, when applied in a proper application within specified ratings. This guarantee is limited to repair or replacement F.O.B. our factory. There is no further warranty or implied representation, guarantee, promise or agreement as to any Curtis Instruments product and/or component.