Instruction manual

22 | Page
Copyright © 2009 Curtis Dyna-Fog, LTD.
ENCLOSED SPACE VOLUME vs. FORMULATION VOLUME AND FOGGING TIME
Based on formulation label application rate of:
1 fluid ounce (oz) per 1000 cubic feet (cu. ft.)
100 milliliters (ml) per 100
cubic meters (cu. m.)
Volume of
Enclosed Space
Cu. Ft. (Cu. Meters)
Average Flow Rate*
To achieve “DRY”
Fog Oz/Min (Ml/Min)
Fogging Time
(Seconds)
1000 ( 30) 5 (150) 12
2000 ( 60) 5 (150) 24
3000 ( 90) 5 (150) 36
5000 ( 140) 5 (150) 60
10000 ( 280) 5 (150) 120
20000 ( 560) 5 (150) 240
30000 ( 840) 5 (150) 360
40000 (1120) 5 (150) 480
50000 (1400) 5 (150) 600
TABLE 1
________________________________________________________________
ENCLOSED SPACE VOLUME vs. FORMULATION VOLUME AND FOGGING TIME
Based on formulation label application rate of:
1 fluid ounce (oz) per 3000 cubic feet (cu. ft.)
100 milliliters (ml) per 300 cubic meters (cu. m.)
Volume of
Enclosed Space
Cu. Ft. (Cu. Meters)
Average Flow Rate*
To achieve “DRY”
Fog Oz/Min (Ml/Min)
Fogging Time
(Seconds)
1000 ( 30) 5 (150) 4
2000 ( 60) 5 (150) 8
3000 ( 90) 5 (150) 12
5000 ( 140) 5 (150) 20
10000 ( 280) 5 (150) 40
20000 ( 560) 5 (150) 80
30000 ( 840) 5 (150) 120
40000 (1120) 5 (150) 160
50000 (1400) 5 (150) 200
TABLE 2
* This flow rate is an average. Your actual flow rate required to produce a "dry"
fog may vary depending on the viscosity of the formulation to be fogged, the
formulation tank pressure, and the operating characteristic "dry" fog must be
used when fogging in an enclosed area. See "Dispensing FOG WARNING" on
page 23-25. To test the fog to verify that it is "dry," see "Dry Fog vs. Wet Fog" on
page 27.