Instruction manual
50 | Page
Copyright © 2009 Curtis Dyna-Fog, LTD.
WARNING:
DO NOT push the ignition switch with the spark plug removed.
Symptom: There is no spark when the Ignition Switch is pressed.
Check:
1. The battery may be too weak. Remember, batteries will go dead over a
period of time whether they are used or not.
2. Examine the wiring for loose connections. Is the spark plug boot firmly
attached? Is the ignition module good and tight against its stainless steel
mounting plate? Is the ground wire connection good and tight.
3. If the Ignition Switch begins to go bad, it may work in some positions but not in
others.
4. After 1, 2 and 3 are tried, the only possible remaining source of problems is
the Ignition Coil. Re-check the above before replacing the Ignition Coil.
Symptom: Gasoline does not reach the Antechamber.
Check:
1. The Primer Bulb lines for leaks. By removing the air filter top cover, fuel should
be visible when the bulb is depressed.
2. The Fuel Filter may be clogged.
3. The Fuel Needle may be closed.
4. The machine may be out of gasoline.
5. The On-Off Control may not be properly located for starting the machine.