SERVICE MANUAL C1000AP & C1000APT DUAL AIRPOT BREWERS Wilbur Curtis Co., Inc.
INDEX Subject Page Shipping List . . . . . . . . . . . . . . . . . . . . . . . . . . . Inside Front Cover Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inside Front Cover Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Setting Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Brewing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Care & Maintenance . . . .
C1000AP & C1000APT Airpot Brewer INTRODUCTION This manual applies to Curtis Dual Station Airpot Brewer models C1000AP and C1000APT. Model C1000AP is designed for use with Curtis Airpots CAP-1 thru CAP-5, and other insulated dispensers up to 13¾" tall when opened for filling (see illustration, Step 3 in Coffee Brewing). Starting early in 1994, this brewer was increased in height to accommodate the larger "Deluxe" stainless steel brew cone.
C1000AP & C1000APT Airpot Brewer COFFEE BREWING 1. With a clean filter in place, pour ground coffee into the brew cone. You may need to experiment to determine the correct quantity of ground coffee for your tastes, but a consistent measure of ground coffee is necessary for controlling the quality of flavor in your brewed coffee. 2. Slide brew cone onto the guide rails as far in as it will go. Place an empty airpot beneath the cone.
C1000AP & C1000APT Airpot Brewer CARE AND MAINTENANCE OF C1000 AP Preventive maintenance is essential in keeping your Curtis coffee brewer performing at it's peak. Regular cleaning will pay off with an appealing, high performance, coffee brewing machine. Preventive Maintenance 1. Remove the sprayhead from brewer and clean it once a week; more often in heavy lime areas. 2. The inside of the heating tank may, occasionally, require removing of lime build-up.
C1000AP & C1000APT Airpot Brewer TROUBLE SHOOTING CONTINUED: PROBLEM: WATER DOES NOT FLOW INTO HEATING TANK. POSSIBLE CAUSE SOLUTION 3. Grounded probe When the water level gets below the probe tip, water should automatically refill the tank. If not, pull wire off the probe terminal. Water should now start flowing into the tank. If not, check the water level control board (see step 4) or inlet valve (step 2). 4. Defective water level control board Disconnect wire from probe terminal.
C1000AP & C1000APT Airpot Brewer TROUBLE SHOOTING CONTINUED: PROBLEM: WATER IN TANK DOES NOT REACH PROPER TEMPERATURE SOLUTION POSSIBLE CAUSE 4. Burned out heating element In this coffee brewer there are two elements in parallel. Failure of either will cause very slow heating. Perform the following tests: a. Clamp-on ammeter test: If both elements are good, you will measure about 21 amps at 240 volts or 24 amps at 208 volts. Use heavy wire from the contactor to measure the current.
C1000AP & C1000APT Airpot Brewer ILLUSTRATED PARTS BREAKDOWN [6]
C1000AP & C1000APT Airpot Brewer ILLUSTRATED PARTS BREAKDOWN 43 42 [7]
C1000AP & C1000APT Airpot Brewer PARTS LIST INDEX Nº 1 2 3 4 5 6 7 8 10 11 11A 13 15 15A 20 21 22 23 24 PART Nº WC-5421 WC-1809 WC-1806 WC-3621 WC- 114R WC- 122 WC- 202 WC-6324 WC-2936 WC-37237 WC-37265* WC-6221 WC-5847 WC-5848 WC-4380 WC- 608 WC- 604 WC- 817 WC- 899 DESCRIPTION COVER, TOP SS FAUCET, PS/HPS SERIES HOT WTR SEAT CUP, SILICONE F0R WC-1809 BREW CONE, UNIVERSAL 7.1" DIA.
C1000AP & C1000APT Airpot Brewer [9]
Product Warranty Information The Wilbur Curtis Company certifies that its products are free from defects in material and workmanship under normal use. The following limited warranties and conditions apply: 3 Years, Parts and Labor, from Original Date of Purchase on digital control boards. 2 Years, Parts, from Original Date of Purchase on all other electrical components, fittings and tubing. 1 Year, Labor, from Original Date of Purchase on all electrical components, fittings and tubing.