Programming
Tea Dilution Stir (Factory set to ON).
Press to Select. Press < or > buttons, to toggle between OFF and ON. Press to set.
Tea Pulse Brew (Factory set to OFF).
Press to Select. Press < or > to select ON, OFF or D. D is a manual adjust from 1 to 20 pulses with an ON time
from 5 to 150 seconds and an OFF time from 5 to 150 seconds.
Tea Fast Brew (Factory set to OFF).
Press 

Tea Half Batch (Factory set to OFF).
Press to Select. Press < or > buttons, to toggle between OFF and ON. Press to set.
Tea Drip-Out (Factory set to OFF)
Press to Select. Press < or > to adjust time. Settings are OFF, up to 15 minutes, at one minute increments.
Temperature (Factory set to 204ºF)
Press to Select. Press < or > to increase or decrease setting. Temperature range, from 170ºF to 208ºF in 2-degree
increments.
Energy Save Mode (Factory set to OFF)
Press to Select, < or > ON, OFF or ON 140ºF , to set. When in ON, unit will automatically shut off 4 hours from
last brew. When feature is OFF, unit does not have the energy saving mode.
In the ON 140ºF position, temperature goes down to 140ºF. if unit has not brewed in 4 hours. This feature will save
energy by maintaining a lower temperature in the tank during periods of non-operation.
Brew Count Odom.
Press to Select, Shows total gallons and total brew cycles on the unit. Press ex or Reset Brew Count Total.
Brew Count Total
Press to Select, Shows total gallons and total brew cycles on the unit. Cannot be reset.
Cold Brew Lock (Factory set to 5º F)
Press to select, < or > to select desired setting (CBL 5, 15 or OFF), to set.
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point.

set point for the Ready to Brew message, however it will brew at any temperature.
Master Reset
Press to display Are You Sure? Then < for Yes, > for No. When Master Reset is used, the all of the menu selec-
tions in the UCM return to factory defaults.
Service Call (Phone number Factory set to 1-800-000-0000)
Press to display number and change number or < to move place and EX to exit when complete. This number will
be displayed during a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code (Factory set to 1-2-3-4)
Press to display number and change number, (the number can be changed 1 to 4) or < to move place and ex to exit
when complete.
Temperature
Tea Dilut Stir

Brew Count Odom

Service Call
Brew Count Total
Cold Brew Lock
Tea Pulse Brew
Access Code
Tea Fast Brew
Tea Half Batch
Tea Drip-Out