MSDS

MATERIAL SAFETY DATA SHEET
AcrylPro Ceramic Tile
Adhesive
VOC content : 59 g/L.
Section 10: STABILITY AND
REACTIVITY
Stability: Stable under normal storage conditions.
Conditions of Reactivity: Heat. Incompatible materials.
Incompatible Materials: Not available.
Hazardous Decomposition Products: May include, and are not limited to: oxides of carbon.
Possibility of Hazardous Reactions: No dangerous
reaction
known under conditions of normal use.
Section 11: TOXICOLOGY
INFORMATION
EFFECTS OF ACUTE EXPOSURE
Component Analysis
Ingredient LD
50
(oral) LC
50
Silica, crystalline, quartz
Ethylene glycol
Calcium carbonate
500 mg/kg, rat
4700 mg/kg, rat
6450 mg/kg, rat
Not
available.
> 200 mg/m³ 4hr,
rat
Not
available.
Eye: May cause eye irritation.
Symptoms
may include discomfort or pain, excess blinking
and tear production, with marked redness and swelling of the conjunctiva.
Skin: May cause skin irritation. Symptoms may include redness, drying, and cracking
of the skin.
Ingestion: May be harmful if swallowed. May cause stomach distress, nausea or vomiting.
Inhalation: May cause respiratory tract irritation.
EFFECTS OF CHRONIC EXPOSURE
Target Organs: Not available.
Chronic Effects: Hazardous by
W
HMIS/OSHA criteria.
Carcinogenicity: Hazardous by
W
HMIS/OSHA criteria.
Ingredient Chemical Listed as Carcinogen or
Potential Carcinogen *
Silica, crystalline, quartz G-A2, I-1, N-1, CP65
Ethylene glycol Not listed.
Calcium carbonate Not listed.
* See Section 15 for more information.
Mutagenicity: Not hazardous by
W
HMIS/OSHA criteria.
Reproductive Effects: Not hazardous by
W
HMIS/OSHA criteria.
Developmental Effects:
Teratogenicity: Hazardous by
W
HMIS/OSHA criteria.
Embryotoxicity: Hazardous by
W
HMIS/OSHA criteria.
Respiratory Sensitization: Not hazardous by
W
HMIS/OSHA criteria.
Skin Sensitization: Not hazardous by
W
HMIS/OSHA criteria.
Toxicologically Synergistic Materials: Not available.
4 /
7