Specification
TILING 09 30 00 Surface Prep / TDS-107
Bonding to Plywood Surfaces
Plywood floors, including those under resilient flooring, must be
structurally sound and must meet all ANSI A108.01 Part 3.4
requirements. See TCNA F150. For questions about proper subfloor
installation,callCustom®BuildingProducts.
Forametallath,fastenevery6"–8"(15–20cm)withfastenersthat
have a galvanized or corrosion-resistant coating. For a 23/32" (18.2
mm) plywood subfloor with 24" (61 cm) o.c. joists, the metal lath must
beaminimumof2.5lb/yd²(1.13kg/M²).Allplywoodseamsshouldbe
gapped 1/8" (3 mm) and protected by placing a minimum 1.5" (38
mm) bond breaker tape over the gaps.
OSB Underlayments
OSBunderlaymentsshouldbecoatedwith10–15milsofRedGard®
Waterproofing and Crack Prevention Membrane. Metal lath must be
fastenedtotheOSBever6"–8"(15–20cm).Aminimumof1/4"(6
mm)ofLevelLite®canbeappliedoverthisproperlypreparedOSB.
Bonding to Cutback Adhesive
Adhesive layers must be removed, as they reduce mortar bond
strength to cement surfaces. Use extreme caution; adhesives may
contain asbestos fibers. Do not sand or grind adhesive residue, as
harmful dust may result. Never use adhesive removers or solvents, as
they soften the adhesive and may cause it to penetrate into the
concrete. Adhesive residue must be wet-scraped to the finished
surface of the concrete, leaving only the transparent staining from the
glue. To determine desirable results, do a test bond area before
starting. Refer to the RFCI Pamphlet, Recommended Work Practices
for Removal of Resilient Floor Coverings, for further information.
Priming
PrimeallsurfaceswithLevelQuik®LatexPrimerbeforeapplication.
Expansion Joint placement
Expansion joints and cold joints, as described in ANSI A108.01, should
never be bridged with setting material. They must be brought through
the tile work and filled with an appropriate elastomeric sealant, such
asCustom's®100%Silicone.ContactCustom'sTechnicalServicesfor
the proper treatment of control or saw cut joints. Refer to TCNA
EJ171, F125 & F125A.
Mixing Ratios - powder to water
Mix the entire 30 lb (13.6 kg) bag of powder with 5 1/2 to 6 quarts
(5.2-5.7 L) of clean, cool water.
Mixing Procedures
Slowly add powder to the water while mixing with a heavy-duty 1/2"
(13 mm) electric drill and mixing paddle at 500 RPM. Thoroughly mix
for 2 minutes to a lump-free consistency.
Application of Product
ApplyLevelQuik®LatexPrimerwithapaintbrush,shortnaprolleror
soft-push broom. Apply a thin even coat and allow to dry
approximately 2 hours to a clear film. Pour or pump, and then spread
withalonghandledgaugedspreader.LevelLite®willseekitsown
level during the first 10 minutes. For feather edging and touch up, use
asmoothingtool.LevelLite®canbeappliedto2"(5cm)thickinone
application; if a second layer is required, install immediately after the
first layer has set to a walkable hardness. If the first layer has dried
over 12 hours, re-prime before the second application. For installation
on wood subfloors with joists to 24" (61 cm) o.c., apply a 1/2" (13
mm)thicklayerofLevelLite®over3/4"(19mm)ExteriorGrade
Plywood with a properly fastened metal lath. For pumping and large
scaleapplications,contactCustom's®TechnicalServicesDepartment
for more information.
Curing of Product
LevelLite®driestoawalkablehardnessin24hours.Forceramictile
and stone, allow 4 hours; for impervious floor coverings, allow 14
hours. Drying times can vary with temperature and humidity. Test for
moisture content before applying vinyl or wood flooring.
Cleaning of equipment
Clean with water before the material dries.
Health Precautions
This product contains Portland cement and free silica. Wear rubber
gloves and eye protection. Avoid eye contact or prolonged contact with
skin and wash thoroughly after handling. If eye contact occurs, flush
with water for 15 minutes and consult a physician.
Conformance to Building Codes
Installation must comply with the requirements of all applicable local,
state and federal code jurisdictions.
6 Availability & Cost
Item Code Size Package
LLSLU30 30 lb (13.6 kg) Bag
7 Product Warranty
Custom®BuildingProductswarrantstotheoriginalconsumer
purchaser that its product shall be free from defects in material and
workmanship under normal and proper usage for a period of one year
followingthedateoforiginalpurchase.Custom's®soleliabilityunder
this warranty shall be limited to the replacement of the product. Some
states, countries or territories do not allow the exclusion or limitation
of incidental or consequential damages, so the above limitation or
exclusion may not apply to you. This warranty will not extend to any
product which has been modified in any way or which has not been
usedinaccordancewithCustom's®printedinstructions.Custom®
makes no other warranties either expressed or implied. This warranty
gives you specific legal rights, and you may have other rights that vary
from state to state or from one country/territory to another. Click for
details and complete warranty information.
LevelLite®SelfLevelingUnderlayment
Published Date: 10/17/2013