TDS
LevelLite®SelfLevelingUnderlayment/TDS107
Limitations to the Product
When using over lightweight concrete or gypsum underlayment,
the surface must first be prepared with RedGard®Waterproofing
and Crack Prevention Membrane.
Donotusewhenthetemperatureisbelow50°F(10°C)orabove
90°F(32°C).
Do not use on sloped surfaces that require drainage.
This product is not meant for use as a wear surface.
Precautions should be taken when applying over post-
tensioned concrete, pre-stressed concrete or prefabricated concrete
planks. Contact CUSTOM technical services for further details.
Do not bond directly to hardwood, Luan plywood, particle
board, parquet, cushion or sponge-back vinyl flooring, metal, fiberglass
or plastic. Contact CUSTOM technical services for recommendations.
For installations over metal decks, contact CUSTOM technical services
for recommendations.
Packaging
30 lb (13.6 kg) Bags
4 Technical Data
Applicable Standards
ASTM International (ASTM)
ASTM C1708 Standard Test Methods for Self-leveling
Mortars Containing Hydraulic Cements
ASTM C627 Standard Test Method for Evaluating Ceramic Floor
Tile Installation Systems Using the Robinson-Type Floor Tester
ASTM F1869 Standard Test Method for Measuring Moisture
Vapor Emission Rate of Concrete Subfloor Using Anhydrous
Calcium Chloride
American National Standards Institute (ANSI) ANSI A108.01 A108.02 of
the American National Standards for the Installation of Ceramic Tile
Resilient Floor Covering Institute (RFCI) Recommended Work Practices
for Removal of Resilient Floor Coverings
Tile Council of North America (TCNA) TCNA Handbook for Ceramic Tile
Installation, TCNA Method EJ171
Technical Chart
Property Test Method Typical Results
Pot Life 30 Minutes
Flow Time 10 Minutes
Initial Set ASTM C-191 90 Minutes
Final Set ASTM C-191 3-1/2 Hours
Compressive Strength ASTM C-109 4600 psi (3.23 MPa)
Flexural Strength ASTM C-109 1100 psi (7.58 MPa)
Walkable Hardness 2 - 4 Hours
Time Before Installing Floor Covering
Ceramic Tile 4 Hours
Other Floor Covering 14 Hours
Robinson Test ASTM C-627 Extra Heavy
Installed Density - Dry approx. 80 lbs/cu ft
Environmental Consideration
Custom®BuildingProductsiscommittedtoenvironmental
responsibility in both products produced and in manufacturing
practices.UseofthisproductcancontributetowardsLEED®v3
certification:
Up to 2 points towards MR Credit 5, Regional Materials
Up to 2 points towards MR Credit 4, Recycled Content
5 Instructions
General Surface Prep
USE CHEMICAL-RESISTANT GLOVES, such as nitrile, when
handling product.
All surfaces must be structurally sound, clean, dry and free from
contaminants that would prevent a good bond. Concrete must be fully
cured. Concrete surfaces should be primed with LevelQuik Latex
Primer. Smooth concrete surfaces, existing glazed tile, terrazzo, or
polished stone may need to be roughened or scarified. For increased
performance in demanding applications, concrete surfaces can be
mechanically profiled and prepared by shotblasting, sandblasting,
water-jetting, scarifying, diamond-grinding or other engineered
approved methods (reference ICRI CSP 3 standards for acceptable
profile height). CUSTOM's MBP Multi-Surface Bonding Primer may be
used as an alternative to profiling the surface.
Bonding to Concrete Surfaces
Contaminants or curing compounds should be mechanically
removed before installation. Concrete must be free of efflorescence
and not subject to moisture beyond the floor covering manufacturers'
limits or hydrostatic pressure. Lightweight concrete surfaces must have
atensilestrengthinexcessof200psi(1.4n/mm²).
Bonding to Plywood Surfaces
Plywood floors, including those under resilient flooring, must
be structurally sound and must meet all industry guidelines.
For questions about proper subfloor installation, call Custom
TechnicalServices.A2.5lb/yd²metallathmustbefastenedevery6"
8" (15 - 20 cm) with fasteners that have a galvanized or corrosion-
resistant coating over primed surface.
OSB Underlayments
OSB underlayments should be coated with 10-15 mils of
RedGard®WaterproofingandCrackPreventionMembrane prior to
priming with LevelQuik Latex Primer.A2.5lb/yd²metallathmustbe
fastened every 6" - 8" (15 - 20 cm) with fasteners that have a
galvanized or corrosion-resistant coating. A minimum of 1/4" (6 mm)
of LevelLite can be applied over this properly prepared OSB.
Bonding to Gypsum Surfaces
LevelLite®SelfLevelingUnderlayment
Published Date: 3/28/2018