Specifications
36
RATING PLACARD
Per NFPA-1901, a permanent hose & hose reel rating specification placard shall be installed adjacent to
each hydraulic reel.
HYDRAULIC RESCUE TOOL HIGH PRESSURE SUPPLY HOSE, 100 FT. SECTIONS
Two (2) each, 100' sections of 1/4" inside diameter 10,000 PSI working pressure twin line rescue tool
hydraulic supply hose to be furnished, equipped with quick disconnect couplings. Hose assemblies shall
be compatible with the purchaser's high-pressure rescue tools.
HYDRAULIC HOSE QUICK-COUPLERS, BRAND SPECIFIC
The specified Hydraulic Rescue Tool Hose Reel hose to be equipped with Hurst brand Quick-Couplers on
the hose ends.
SOURCE OF POWER FOR HYDRAULIC HOSE REEL(S)
The truck builder shall build into the body design a location for the Hurst hydraulic pump as specified in
the equipment options part of this proposal. The above specified rescue tool hydraulic hose reel(s) shall
be plumbed to this location so they can be hooked to the Hurst hydraulic pump.
START SWITCH, FOR HYDRAULIC POWER SUPPLY
A single remote start switch is to be furnished, to activate power to the on-board line voltage hydraulic
rescue tool power source. Switch is to be mounted inside the bumper extension rescue tool compartment
accessible through open compartment door. Switch to be labeled with permanently engraved nameplate
identifying function.
125-VOLT RECEPTACLE(S)
One (1) each 125-volt 3-wire household weatherproof plug-in receptacle to be furnished, mounted inside
the bumper extension rescue tool compartment, accessible through open compartment door. Receptacle to
include: metal cover plate, cast aluminum electrical receptacle box, screw type conduit connector, and
flexible non-metallic electrical conduit with appropriate size multi-stranded THHN insulated copper
wiring extending from receptacle to specified generator circuit breaker panel. Receptacle to be provided
with individual manual reset circuit breaker. Receptacle outlet to be labeled with permanently engraved
nameplate identifying voltage.
EXHAUST OUTLET PASSENGER SIDE
The original chassis engine exhaust system, upstream of the outlet, shall NOT be modified, so as to
remain in compliance with 2010 exhaust emission standards. System shall be designed and installed to
prevent component interference with the specified fire pump installation and compartment
floors/runningboards. Fabricated steel or aluminum heat deflector plates shall be provided where
necessary to protect these same components from excessive radiant heat. Exhaust outlet shall terminate
below body compartment floor ahead of rear wheels on passenger side of vehicle to be compatible with
the Fargo Fire Departments Nederman system.