Specifications
49
HOSE CAPS AND REDUCING ADAPTERS
Two (2), each 2-1/2" NST female x 1-1/2" NST male chrome plated brass rocker lug reducing adapters,
with 1-1/2" NST hose caps with chains shall be furnished, in exchange for the same quantity of
previously specified 2-1/2" hose caps with chains.
TOP DELUGE DISCHARGE - HAND CRANK VALVE
One (1), top (above pump) gated deluge discharge to be provided with: 3" riser outlet thread/flange, 3"
i.d. stainless steel stationary riser pipe, 3/4" bronze "auto-drain" valve located immediately downstream of
gate valve, 3-1/2" Akron "ELECTRIC ACTUATOR OPERATED" 1/4-turn discharge valve with chrome
plated ball and spring loaded self-adjusting seal assembly (located inside pump compartment), operator's
panel mounted valve control console with spring loaded open/close toggle switch and
"OPEN/MULTIPLE-TRANSITION/CLOSED" indicator light.
DELUGE MONITOR
A 1000 GPM TFT Crossfire Monitor (model xfc-62 package) shall be plumbed in and mounted above
pump compartment, this shall have a quick release mount so it can be removed and placed in a portable
base with two (2) 2 ½” inlets that will be provided by builder. The setup of the monitor will be discussed
at pre-build.
Monitor shall have manual free-swivel and wheel controlled elevation.
FIRE PUMP COMPARTMENT
The fire pump compartment location shall be determined by the manufacture. This apparatus is to have
either a rear pump location or a mid mount style pump location. Depending on how the apparatus is
configured, its features and accessories should include the following:
3D ENGINEERED REAR PUMP ENCLOSURE
The following specified fire pump enclosure (compartment) is to be "fully engineered" as an integral part
of the compartmented apparatus body, with ALL structural fabrications, pump inlet/outlet panels, pump
control panel, gauge/instrument panel, hose beds/trays, and fire pump mounting brackets are to be
computer three-dimensional modeled and on-screen assembled. Each individual pump module
component's part profile is to be traceable to a precision engineered digital drawing.
In addition to the part profile and fabrication details, the precision engineering is to include the mounting
and fastener holes to allow the assembly of all related fire pump compartment components, including but
not limited to: gauges and instrumentation, pump drain and bleeder controls, pump discharge and suction
valve controls, handrail bracket and step mount holes, and all other accessories which are to be bolted to
the pump module.
SPEEDLAY HOSEBEDS
The following specified speedlay hose beds shall be located in the forward lower portion of apparatus
body, behind the cab.
REMOVABLE POLY SPEED LAY HOSE BEDS
Three (3), horizontal modular and removable speed-lay hose beds shall be provided, fabricated of 1/2"
thick Poly.