Specifications

50
Hose beds shall be accessible for loading via removable "speed lay hose beds". There shall be two (2)
removable "speed lay hose beds" designed to accommodate 200 ft. each of 1-3/4" double jacket fire hose.
There shall be one (1) removable "speed lay hose beds" designed to accommodate 200 ft of 2 1/2" double
jacket fire hose.
4-way mirror finish stainless steel cartridge cavity surrounds shall be provided, driver and passenger side,
to protect side panels during hose deployment and installation of cartridge hose beds.
The specified speed lay swivel style discharge outlet shall be located "overhead" the hose bed floor,
allowing hose coupling to the outlet after installing the loaded cartridge.
Swivel outlet shall also allow for deployment of the pre connected hose, to left and right sides of the
vehicle.
SPEEDLAY 2-1/2" VALVE, 1-1/2" NST OUTLET
two (2), forward horizontal speed-lay 2" gated discharge to be provided with: 1-1/2" NST male outlet x 2-
1/2" inlet 90 degree bronze or stainless steel overhead discharge swivel, hoseline bleeder valve, 2" i.d.
stainless steel pipe or wire reinforced hose with 2" stainless end fittings, 2-1/2" Akron 1/4-turn discharge
valve with chrome plated ball and spring loaded self-adjusting seal assembly (located inside pump
compartment), and push-pull chrome "twist-to-lock" discharge control handle with recessed color coded
nameplate located on the pump operator's control panel.
SPEEDLAY 2-1/2" VALVE, 2-1/2" NST OUTLET
One (1),forward horizontal speed-lay 2 1/2" gated discharge to be provided with:2-1/2" NST male outlet x
2-1/2" inlet 90 degree bronze or stainless steel overhead discharge swivel, hoseline bleeder valve, 2 1/2"
i.d. stainless steel pipe or wire reinforced hose with 2 1/2" stainless end fittings, 2-1/2" Akron 1/4-turn
discharge valve with chrome plated ball and spring loaded self-adjusting seal assembly (located inside
pump compartment), and push-pull chrome "twist-to-lock" discharge control handle with recessed color
coded nameplate located on the pump operator's control panel.
SWING-OUT VERTICAL HOSE ROLLERS
Front speed-lay cavity openings, driver side and passenger side, shall include swing-out panel mounted
vertical polished tubular stainless steel hose roller assemblies. With panels in extended position, the
rollers shall prevent damage to the door jamb weather-stripping. Hose rollers are to be in addition to the
specified mirror finish stainless edge protection.
FOAM SYSTEM, DIRECT DISCHARGE
DUAL AGENT FOAM SYSTEM
The following specified Direct Discharge Foam System shall be of the "dual agent" type, with features
and accessories as per the following: