Specifications
54
MASTER GAUGES, VACUUM & PRESSURE
NO-SHOK LIQUID FILLED GAUGES
Master pump intake and pump discharge pressure indicating devices shall be located within 8" of each
other, edge to edge, with the intake (suction) pressure indicating device to the left of the pump discharge
pressure indicating device.
A 4" diameter NoShok compound style pressure gauge to be furnished, registering 0 x 600 psi, black
numerals on white background. Gauge needle shall have a "bright orange" tip for improved visibility.
Gauge to be piped to discharge volute of fire pump, equipped with a black permanently engraved
identification nameplate installed below the gauge, to read: "DISCHARGE."
A 4" diameter NoShok compound style pressure gauge to be furnished, registering -30 x 400 psi, black
numerals on white background. Gauge needle shall have a "bright orange" tip for improved visibility.
Gauge to be piped to suction volute of fire pump, equipped with a black permanently engraved
identification nameplate installed below the gauge, to read: "SUCTION."
TEST GAUGE PANEL
A test plug assembly to be furnished and installed on specified gauge panel adjacent to respective pump
suction and pump discharge gauge. Test plugs to be piped to pump suction cavity and discharge cavity
using high pressure clear nylon tubing with brass fittings.
INDIVIDUAL DISCHARGE GAUGES, 2-1/2" DIAMETER
A 2-1/2" diameter NoShok compound style discharge pressure gauges to be furnished for each individual
discharge. They shall register 0 x 400 psi, black numerals on white background. Gauge needle shall have
a "bright orange" tip for improved visibility. Gauges to be located in a uniform manner no more than 6"
from its respective discharge valve control.
Each gauge and respective discharge valve control to be equipped with color coded permanently engraved
identification nameplate to describe numerical sequence, location, type and size of outlet.
WATER LEVEL INDICATOR - TANK VISION
One (1), FRC, "Tankvision" WLA-200-A water tank level indicator to be furnished with: weatherproof
encapsulated high intensity LED light indicator, tank level sending unit, and protected wiring loom.
Water tank level indicator to be mounted on pump control panel.
FOAM LEVEL - INDICATORS - TANKVISION-2 EACH
Two (2), FRC, "Tankvision" foam tank level indicators to be furnished with: weatherproof encapsulated
high intensity LED light indicator, 30-ft sensor cable extension for foam tank level indicator, tank level
sensing probe, and protected wiring loom. Foam tank level indicators to be mounted on pump control
panel.
POLY WATER TANK -- LIFETIME WARRANTED - 750 WATER
The apparatus shall be equipped with a 750 gallon water capacity polypropylene thermoplastic water
tank.