Specifications
65
ILLUMINATION OF HAZARD WARNING LIGHT(S)
The above specified Hazard Warning Light(s) shall illuminate only when the park brake has been
released, so as to alert driver of pending hazard. Warning light(s) shall remain off with vehicle parked;
"on scene".
LED LIGHT STRIPS UNDERSIDE ALUMINUM HOSEBED COVERS
Four (4) 12-volt multiple LED element, "underside" metal hosebed cover horizontally mounted "strip"
tubular lights, shall be furnished. Light strips are to be positioned, one (1) at each front and back top
corner of the folded-open hosebed covers. Light strips shall be activated by a single pump operator's
panel mounted illuminated rocker switch.
LED LIGHT STRIPS UNDERSIDE POD COVERS
One (1) each, 12-volt multiple LED element tubular light strips, are to be furnished, mounted one (1) per
cavity pod, underside the hinged metal pod covers. Light strips are to be positioned to illuminate interior
pod cavity, with the hinged cover in full-open position. Light strips are to be activated by opening of
respective pod cover.
Breathable Air System
Shall be a 6000 PSI CASCADE SYSTEM.
AIR STORAGE BOTTLES
Four (4) 6000 PSI DOT 509 cu. ft. air storage tanks shall be furnished. Air Bottles are to be approved by
DOT/IO/UN for Breathing Air Storage.
Air purity in tanks shall meet or exceed the standard of the Compressed Gas Association Specifications
G-7.1 for Grade "E" Breathing Air. All tubing shall meet NFPA, SAE, JIC and ANSI standards. All
valves shall meet the applicable National Codes such as those of DOT and CGA. All major components
and accessories are to be clearly identified with permanently affixed nameplates stating the make, model,
and serial number. Appropriate tags and warning labels shall be affixed where necessary for safety and
ease in the operation and adjustment of the valves, switches, and controls.
A placard is to be affixed in the vicinity of the cascade control panel indicating the date of the required
hydrostatic test of the DOT cylinders.
CASCADE FILL PANEL
All gauges shall read 7500 PSI. All high pressure tubing, hoses, and valves shall be rated at 6000 PSI
working pressure with a 4:1 safety factor. All metal stainless steel tubing shall be fully annealed and
suitable for bending, clamped every 36" or less to prevent chafing.
A custom built fill station instrument panel shall be provided, to include the following:
1. Seven (7), liquid filled 2-1/2", 0-7500 PSI gauges, one (1) for each of the four (4) 6000 PSI air banks
one (1) for adjustable regulator, one (1) for supply pressure, and one (1) for filled SCBA bottle
pressure.