Specifications
74
stranded color coded THHN insulated wiring. All circuits shall be identified with nameplates describing
controlled function.
RECESSED LINE VOLTAGE SCENE LIGHTS, 240 VOLT, 1500 WATT
Six (6) Fire Research "Optimum" model OPA250-M15 1500W/240-volt 4" deep-recessed quartz
floodlight(s) to be furnished complete with tilt-down optics. Light(s) to be wired and powered by
generator load center mounted 12-volt/240-volt relays with remote illuminated, 12-volt rocker switches.
Light(s) relay switch to be mounted: circuit breaker box identified as: "side" and "rear floodlights
240V RECESSED LIGHT LOCATION(S)
The above specified 240V Recessed light(s) shall be located, two (2) on the driver’s side of the body as
high and forward and back as possible: two (2) on the passenger’s side of the body as high and forward
and back as possible, and two (2) on the back of the body as high and out to each side as possible. These
lights shall be able to be turned on and off from both the emergency light control panel in the cab and
from the pump operator’s panel. The lights shall be turned on in the pairs as stated above.
POWER REWIND ELECTRIC CORD REEL(S)
LINE VOLTAGE ELECTRIC CORD REEL(S), 120-VOLTS AC
Two (2) each, Hannay model ECR1614-17-18 or equivalent, 12-volt electric chain and sprocket rewind
"live-wire" 120VAC electric 3-conductor cord reel(s) shall be furnished, painted with oven-cured enamel
standard silver metallic color. Cord reel(s) shall be equipped with a placarded weatherproof push-button
12-volt rewind switch located within easy reach of the operator while standing on the ground outside the
vehicle.
POWER FEED LINE AND CORD/CABLE
A voltage & amperage matching capacity insulated and conduit protected multi-stranded copper power
feed line shall extend from the reel's junction box to the specified circuit breaker panel. Cord reel shall
receive its own dedicated manual-reset circuit breaker, of specified capacity.
Each reel shall be provided with a single 150 ft. section of 12/3 S.O. insulated multi-stranded copper
electric cord. The electric cord shall be mechanically clamped at and connected to the reel drum power
leads, and provided with an opposite end cord mounted bright orange nylon ball stop.
CORD ROLLERS
Each electric cord reel shall be equipped with a "captive" 4-way cord roller assembly, angled towards the
ground level, for ease of cord deployment and rewinding. The roller assembly shall be of same or slightly
narrower width as reel drum, in order to prevent cord from crawling over the reel discs while being
deployed and rewound.
GFE RECEPTACLE BOX, HARDWIRED
Two (2)each, Circle-D model PF51G-1 "lighted" electrical receptacle box to be furnished, mounted on
end of specified reel cord(s), each box equipped with: four (4) individual receptacles: 5-20R "household"
female 20-amp/125-volt 3-wire 2-pole receptacles, cord clamp, spring loaded receptacle covers, and
signal light (to indicate power on).