Installation manual
14
CYB-KLED CyberSuite Installation Manual 
TIMING (MENU 1) 
ALL 3 Digits of the timer value MUST be entered when 
programming a timer. This means that for addresses below 
100, you must enter [0] then the 2 digits of the address. For 
addresses below 10, you must enter [0] , [0] followed by the 
address digit. 
Entry Delay Timer ([MENU] [1], [1]) 
The entry delay timer is programmable from 000 to 255 seconds 
(Default 30 Seconds). 
To program the timer value, press 
[MENU] , [1] , [1] , [TIM 1], [TIM 2] , [TIM 3] , [ENTER] 
Where TIM 1 ~ 3 are the timer value digits, entered using the 0 to 9 
number keys. 
Programming the entry delay timer to 0 will result in no entry delay 
operation for any zone that has been assigned the entry delay zone 
type. 
Exit Delay Timer ([MENU] , [1] , [2]) 
The exit timer is programmable from 000 to 255 seconds (Default 30 
Seconds). 
To program the timer value, press 
[MENU] , [1] , [2] , [TIM 1], [TIM 2] , [TIM 3] , [ENTER] 
Where TIM 1 ~ 3 are the timer value digits, entered using the 0 to 9 
number keys. 
Programming the exit delay timer to 0 will result in no exit delay, the 
system will immediately arm the CyberSuite System. 