Installation manual
25  CYB-KLED CyberSuite Installation Manual
    Use this to set the zone type for a motion detector  
   that is located in an entrance area. 
4  Instant  Zone will cause an alarm immediately. 
5  24HR   Zone will always cause an alarm immediately. 
6 Fire  Zone is a fire zone and will generate  an  instant 
alarm. 
7 Fire Delay  Zone is a delayed fire zone and will generate the 
fire delay beeping and require the user to follow 
the delay fire zone procedures to prevent a full fire 
alarm from being activated. 
Zone Options 
The zone options select functions that relate to the operation of 
bypassing, force arming and stay arming. 
Once you have selected a Zone Type for your selected zone, you 
must select the Zone Options. 
To toggle options press the keys [1] to [8] , and the corresponding 
Zone LED will be lit when that option is ENABLED. 
Pressing the [ENTER] key will save the options. 
Option 1 - Bypass Allowed 
5  Enabled the zone can be bypassed. A fire zone can 
never be bypassed regardless of the bypass setting. 
6  Disabled zone can not be bypassed. 
Option 2 - Stay Zone 
5  Enabled the zone is set as a stay zone. When the 
system is armed in stay mode this zone will not 
generate an alarm. 
6  Disabled the zone is not a stay zone. 