CP1300/1500EPFCLCD User’s Manual K01-0000197-00
IMPORTANT SAFETY INSTRUCTIONS This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS. CAUTION! The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection. DO NOT plug the UPS into an outlet that is not grounded. If you need to de-energize this equipment, turn off and unplug the UPS.
CP1500EPFCLCD,). If the rated unit capacities are exceeded, an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip. BASIC OPERATION DESCRIPTION 1. Power Switch Used as the master on/off switch for equipment connected to the battery power supplied outlets. 2. Power On Indicator This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes. 3.
The unit has three battery powered/surge suppression outlets for connected equipment to ensure temporary uninterrupted operation of your equipment during a power failure. (DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other large electrical devices into the “Battery and Surge Protected Outlets”. The power demands of these devices may overload and damage the unit.) 12. Full-Time Surge Protection Outlets The unit has three always on surge suppression outlets. 13.
CYBERPOWER GREENPOWER UPS™ TECHNOLOGY CyberPower’s Green Commitment CyberPower is dedicated to the development of green products, and has adopted Green practices throughout its business, including: membership in Climate Savers Computing Initiative (CSCI), accordance with the Restriction on Hazardous Substances (RoHS), Waste Electrical and Electronic Equipment (WEEE) protocols, as well as ISO 14001 and IECQ QC080000.
red wire and one black wire) to the connector from the battery pack. 9. Put the batteries back into the compartment. 10. Slide back the battery compartment cover and tighten the retaining screw. 11. Recharge the UPS for 8-16 hours to fully charge the battery. REMINDER: Batteries are considered HAZARDOUS WASTE and must be disposed of properly. Almost any retailer that sells lead-acid batteries collects used batteries for recycling. CP1300EPFCLCD CP1500EPFCLCD DEFINITIONS FOR ILLUMINATED LCD INDICATORS 1.
5. 6. 7. 8. 9. 10. 11. 12. 13. 14. BATTERY capacity: This meter displays the approximate charge level (in 20% increments) of the UPS’s internal battery. During a blackout or severe brownout, the UPS switches to battery power, the BATTERY icon appears, and the charge level decreases. FAULT: This icon appears if there is a problem with the UPS. Press the POWER button to turn off the UPS. F01: Battery Mode or AC/Utility Power Mode Overload fault (Turn on the UPS again.
TECHNICAL SPECIFICATIONS Model Capacity (VA) Input Frequency Range AVR Function Output On Battery Output Voltage On Battery Output Frequency Overload Protection Surge Protection Lightning / Surge Protection Network/ Phone/ Fax/ Modem Protection Operating Temperature Physical Total # of UPS outlets Maximum Dimensions(LxWxH) Weight (kg) Battery Battery Typical Recharge Time Charging Current(Max.
TROUBLESHOOTING Problem Circuit breaker button is projecting from the back of the unit. The UPS does not perform expected runtime. Possible Cause Circuit breaker has tripped due to an overload. Battery not fully charged. Battery is slightly worn out. The on/off switch is designed to prevent damage by rapidly turning it off and on. The UPS will not turn on. Solution Turn the UPS off and unplug at least one piece of equipment.