5. BATTERY capacity: This meter displays the approximate charge level (in 20% increments) of the
UPS’s internal battery. During a blackout or severe brownout, the UPS switches to battery power,
the BATTERY icon appears, and the charge level decreases.
6. FAULT: This icon appears if there is a problem with the UPS. Press the POWER button to turn off
the UPS.
F01: Battery Mode or AC/Utility Power Mode Overload fault (Turn on the UPS again.)
F02: Battery Output Short fault (Turn on the UPS again.)
F03: Charger Fault (Contact CyberPower Systems for support.)
F04: Internal Fault (Contact CyberPower Systems for support.)
7. OVER LOAD: This icon appears and an alarm sounds to indicate the battery-supplied outlets are
overloaded. To clear the overload, unplug some of your equipment from the battery-supplied
outlets until the icon turns off and the alarm stops.
8. SCHEDULE: Users can setup the schedule to turn on and shut down the computer and UPS
through PowerPanel
®
Personal Edition software. The LCD display will show how much time that
the UPS is about to turn on or shut down.
9. ESTIMATED RUNTIME: This displays the run time estimate of the UPS with current battery
capacity and load.
10. OUTPUT meter: This meter measure, in real time, the AC voltage that the UPS system is
providing to the computer, such as normal AC line mode, AVR mode, and battery backup mode.
(Note: The OUTPUT meter shows the status of the battery backup outlets in terms of load,
frequency, and voltage.)
11. INPUT meter: This meter measures the AC voltage that the UPS system is receiving from the
utility wall outlet. The UPS is designed, through the use of automatic voltage regulation, to
continuously supply connected equipment with stable, 220/230 output voltage. In the event of a
complete power loss, severe brownout, or over-voltage, the UPS relies on its internal battery to
supply consistent 220/230 output voltage. The INPUT meter can be used as a diagnostic tool to
identify poor-quality input power.
12. EVENT: This meter records the number of power outages.
13. MUTE: This icon appears whenever the UPS is in silent mode. The buzzer does not beep during
silent mode until the battery reaches low capacity.
14. AVR (Automatic Voltage Regulation): This icon appears whenever your UPS is automatically
correcting low AC line voltage without using battery power. This is a normal, automatic operation
of your UPS, and no action is required on your part.
For more information about functions setup, please refer to the Function Setup Guide.