User`s manual

Model Value 600E-GP Value 800E-GP Value 1000E-GP
Capacity (VA) 600 800 1000
Capacity (Watts) 360 480 530
Input
Input Voltage Range 160-265Vac
Frequency Range 47~63Hz (Auto Sensing)
AVR Boost @ 200V
Output
On Battery Output
Voltage
Simulated Sine Wave at 230Vac +/-10%
On Battery Output
Frequency
50/60Hz +/-1%
Transfer Time 4ms Typical
Overload Protection On Utility: Fuse & Internal Current Limiting
On Battery: Internal Current Limiting
Surge Protection
Lightning / Surge
Protection
Yes
Operating Temperature 0°C to 40°C
Operating Relative
Humidity
0 to 90% non-condensing
Physical
Total # of UPS outlets (3) IEC 320 C13
Maximum
Dimensions(LxWxH)
320x100x140mm
Weight (kg) 5.1 6.1 6.2
Battery
Sealed Maintenance
Free Lead Acid Battery
12V / 7Ah x1 12V / 8.5Ah x1 12V / 8.5Ah x1
Typical Recharge Time 8 hours
User Replaceable Yes
Status Indicators
Indicators Power On / Using Battery
Audible Alarms On Battery, Low Battery, Overload
Communication
PowerPanel
®
Personal
Edition Software
Windows 7/Vista/XP/2000/Server 2003, Linux
Management
Auto-Charger Yes
Auto-Restart Yes
USB Yes
LED
Alarm
Fuse
Condition
On Off Normal
Normal
Flash Beep Twice Normal
Utility Failure - The UPS is providing
battery power to outlets.
Flash Rapid Beeping Normal
Utility Failure - The UPS is providing
battery power. The rapid beeps indicate
the battery will run out of power shortly.
On/Flash Constant Tone Normal/ Blown
Overload – Occurs when connected
equipment exceeds the rating of the unit.
Turn the UPS off and unplug at lease
one piece of equipment from the UPS.
Check the fuse and do the replacement
if necessary. Turn the UPS on.
CyberPower’s Green Commitment
CyberPower is dedicated to the development of green products, and has adopted
Green practices throughout its business, including: membership in Climate Savers
Computing Initiative (CSCI), accordance with the Restriction on Hazardous
Substances (RoHS), Waste Electrical and Electronic Equipment (WEEE) protocols,
as well as ISO 14001 and IECQ QC080000. CyberPower pledges to provide the
advanced energy solution for the environment and become a leading eco-friendly
organization in the UPS industry.
Reduce Energy Cost with GreenPower UPS
TM
Technology
CyberPower’s goal is not only to provide eco-friendly products but also to bring the best value for consumers.
The advanced energy-saving design improves the operating
efficiency and eliminates waste energy
consumption. As a result, consumers will enjoy significant energy cost savings with the adoption of
GreenPower UPS
TM
technology.
Problem Possible Cause Solution
Battery not fully charged.
Recharge the battery by leaving
the UPS plugged in.
The UPS does not perform
expected runtime.
Battery is slightly worn out.
Contact CyberPower Systems
about
replacement batteries at
service@cpsww.com.au
The on/off switch is designed to
prevent damage by rapidly
turning it off and on.
Turn the UPS off. Wait 10
seconds and then turn the UPS
on.
The unit is not connected to an
AC outlet.
The unit must be connected to a
220-240V 50/60Hz outlet.
The battery is worn out.
Contact CyberPower Systems
about
replacement batteries at
service@cpsww.com.au
The UPS will not turn on.
Mechanical problem.
Contact CyberPower Systems at
service@cpsww.com.au
Fuse is blown due to overload.
Turn the UPS off and unplug at
least one piece connected
equipment. Unplug the power
cord of the UPS then remove the
fuse compartment beneath the
power inlet of the UPS and
replace the blown fuse with a
spare one. Lock the
compartment back to the UPS.
Connect power cord then turn
the UPS on. Make sure that your
spare fuse meets the
specification.
Batteries are discharged.
Allow the unit to recharge for at
least 4 hours.
Outlets do not provide power to
equipment.
Unit has been damaged by a
surge or spike.
Contact CyberPower Systems at
service@cpsww.com.au
The serial/USB cable is not
connected.
Connect the serial/USB cable to
the UPS unit and an open serial
port on the back of the
computer. You must use the
cable that came with the unit.
PowerPanel® Personal Edition is
inactive.
The unit is not providing battery
power.
Shutdown your computer and
turn the UPS off. Wait 10
seconds and turn the UPS back
on. This should reset the unit.
For more information, visit www.cpsww.com.au or contact
CyberPower Systems Australia
E-MAIL: service@cpsww.com.au
Entire contents copyright ©2010 CyberPower Systems B.V., All rights reserved. Reproduction in whole or in
part without permission is prohibited. PowerPanel® and PowerPanel® Plus are trademarks of CyberPower
Systems (USA) Inc.
TECHNICAL SPECIFICATIONS
TROUBLESHOOTING
CYBERPOWER GREENPOWER UPS™ TECHNOLOGY
DEFINITIONS FOR ILLUMINATED LED INDICATORS