User’s Manual for: CPS725SL with USB Interface and PowerPanel™ Software ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT: www.cyberpowersystems.com/FAQs.
TABLE OF CONTENTS Battery Replacement Instructions.....6 LED Indicators………………………..7 Trouble Shooting Guide…………… .8 Specifications…………………………9 Warranty... ... ... ... ... ... ... ... ... ... ..10 Thank you for purchasing a CyberPower Systems Product. To enjoy all the features and benefits of this Uninterruptible Power System (UPS), please read and follow all installation and operation instructions completely. This UPS is designed to provide guaranteed power protection for connected electronic equipment.
CPS725SL Guaranteed Uninterruptible Power System IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS) This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of unit. Read this manual thoroughly before attempting to unpack, install, or operate. CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area, free of conductive contaminants.
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1. 2. 3. Make sure that the total Volt-Amp (VA) requirements of your computer, monitor and peripheral equipment does not exceed 725 VA. Insure that the equipment plugged into the three battery power-supplied outlets does not exceed the UPS unit’s rated capacity(725VA/400W for CPS725SL). If rated unit capacities are exceeded, an overload condition may occur and cause the UPS unit to shut down and the circuit breaker to trip.
CPS725SL Guaranteed Uninterruptible Power System matically shutdown to conserve battery power. Files with auto-assigned names will be saved under C:\PCTemp, where C is the name of your main hard drive. Files that have previously been saved will be saved in their original location. PowerPanel™ is equipped with a Scheduled Shutdown feature which can automatically save and close open files and then shutdown the computer and UPS at a user specified date and time.
10. Click on Start, point to Settings, and then click Control Panel. 11. Double-click on Add / Remove Programs. 12. Click the Install Button, and follow the on-screen instructions. 13. When the installation is completed, remove the floppy disk. For Windows XP (Home and Professional) 1. Click on Start, and then click on Control Panel. 2. Double-click on Power Options, and then click the UPS tab. 3. Set the manufacturer to None. 4. Exit to the desktop and then shutdown your computer. 5.
CPS725SL Guaranteed Uninterruptible Power System PowerPanel™ Log Window (See Figure 3 ) 1. Display Window: This area displays either the Event Log or the Closed Application Information. 2. Event Log: Select this option to view PowerPanel™ events such as program start, program end, power failure and low battery. 3. Closed Application Information: Select this option to view the file names of applications that were saved by PowerPanel™.
Please note: This service must be stopped in order to run PowerPanel™. To disable the service, set the Manufacturer to None. Please note: You must be logged on as an administrator or a member of the administrator’s group to make these changes. Network policies may also prevent you from making these changes. Please contact your network administrator for further assistance. Testing Your UPS System Once you have set up your UPS system, you may wish to test it.
CPS725SL Guaranteed Uninterruptible Power System 7. 8. Disconnect the battery wires from the battery. Install the replacement battery by connecting the red wire to the positive (+) terminal of the battery and connecting the black wire to the negative (-) terminal of the battery. 9. Slide the battery back into the compartment. 10. Replace the outlet cover and the 6 retaining screws. 11. Recharge the unit for 4 – 8 hours to ensure the UPS performs expected runtime.
TROUBLE SHOOTING Problem Possible Cause Solution Full-time surge protection outlets stop providing power to equipment. Circuit breaker has tripped due to an overload. Turn the UPS off and unplug at least one piece of equipment. Wait 10 seconds, reset the circuit breaker by depressing the button, and then turn the UPS on. The UPS does not perform expected runtime. Battery not fully charged. Recharge the battery by leaving the UPS plugged in. Battery is slightly worn out.
CPS725SL Guaranteed Uninterruptible Power System SPECIFICATIONS CPS725SL Capacity 725VA(400W) Input Voltage on Utility 100V to 140V Input Frequency 57 Hz to 63 Hz On-Battery Output Voltage 120Vac ± 5% Transfer Time 4ms Typical Max. Load for UPS Outlets (3 Outlets) 725VA(400W) Max. Load for Full-Time Surge Protection outlets (6 Outlets) 12 Amps On-Battery Output Wave Form Simulated Sine Wave Form Operating Temperature + 32°F to 95° F.
Limited Warranty and Power Control Guarantee In purchasing CPS725SL in the United States or Canada, the original end user receives a Limited Warranty and CyberPower's Power Control Guarantee from Cyber Power Systems (USA), Inc. (for ease of reading, referred to as "CyberPower"). The Limited Warranty and the Power Control Guarantee are intended to be the original end-user's exclusive rights and remedies. The Limited Warranty and the Power Control Guarantee are separate, all though they are related.
CPS725SL Guaranteed Uninterruptible Power System Making a Limited Warranty Claim. To make a Limited Warranty claim on a Product, you must do the following: 1.
1. Complete and return the CyberPower Warranty card or provide reasonable proof of purchase, for example, a sales receipt that establishes you as the original end-user consumer purchaser of the Product. 2. Call CyberPower at (952) 403-9500 or (877) 297-6937 (toll free), write to CyberPower at 5555 12th Ave East, Suite 110, Shakopee, MN 55379, or e-mail CyberPower at claims@cyberpowersystems.com within ten (10) days of the date of the event for which you wish to make a claim for warranty service. 3.
CPS725SL Guaranteed Uninterruptible Power System 2. As to Connected Equipment, the Power Control Guarantee covers only damage within the specific terms of the Power Control Guarantee to Connected Equipment (and only up to the applicable aggregate ceiling amount). 3.
Contact Information: CyberPower's address is 5555 12th Ave East, Suite 110, Shakopee, MN 55379 and its phone number is (952) 403-9500 or (877) 297-6937 (toll free). CyberPower is the warrantor under this Limited Warranty. You may also contact CyberPower on the Internet at www.cyberpowersystems.com.
FCC Notice This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.