EN User’s Manual CPS7500PRO/CPS7500PIE CyberPower North America CyberPower Systems (USA), Inc. 4241 12th Avenue East Suite 400 Shakopee, MN 55379 Tel: 952-403-9500 Fax: 952-403-0009 Website: http://www.cyberpowersystems.com E-mail: sales@cyberpowersystems.com CyberPower Europe CyberPower Systems B.V. Flight Forum 3545,5657DW Eindhoven,The Netherlands Tel: +31 (0)40 2348170 Fax: +31 (0)40 2340314 Website: http://eu.cyberpowersystems.com/ E-mail: sales@cyberpower-eu.
CPS7500PRO/CPS7500PIE SAFETY AND EMC INSTRUCTIONS Safety and EMC instruction This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your Emergency Power System (EPS). CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants.
CPS7500PRO /CPS7500PIE applications or patient care. DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation from the aquarium can cause the unit to short out. DO NOT USE WITH LASER PRINTERS! The power demands of these devices will overload and possibly damage the unit.
CPS7500PRO/CPS7500PIE INSTALLING YOUR EPS Installing your EPS UNPACKING Inspect the EPS upon receipt. The box should contain the following: EPS unit x1; Installation Guide x1; User manual x1; Battery Charger Setup manual x 1; AUTOMATIC VOLTAGE REGULATOR(AVR) When utility power is inconsistent, the EPS would increases low voltage or decrease high voltage to safe 220 volts.
CPS7500PRO /CPS7500PIE BASIC OPERATION BASIC OPERATION CPS7500PRO CPS7500PIE DESCRIPTION 1. AC Outlets EPS PRO/PIE Series have two general plug-in outlets (UK/Schuko/ France) and one terminal outlet for connected equipment which ensures temporary uninterrupted operation of the equipment during a power failure. Max. Output of 1a is 40A ; Max. Output of 1b is 12A for UK socket, 16A for Schuko/French socket. Max. Output wattage of (1a+1b) is 5250W. *Note: Maximum cord length is 10 meters and the cable O.D.
CPS7500PRO/CPS7500PIE Limit input charger current to prevent charger damaged due to overload. 8. Battery Input Wiring Fault LED Battery input wiring fault LED will illuminate and make an audible alarm to indicate the wiring polarity is reversed. 9. Output Selector Output Selector provides four most common operation situations for switch include Normal, Bypass with AVR, Bypass, Off. No matter under what situations, the charger would keep charging external batteries if utility power is still alive.
CPS7500PRO /CPS7500PIE INSTALLATION GUIDE Note: The installation must be done by professionals. 1. Remove the cover from the back of the machine. Step 1 2. Make sure the POWER SW, Output Selector, and the BATTERY SW. are turned off. (Step1) EPS will not function if the Output Selector is OFF. Make sure the Selector on Normal position after all installation procedures. Step 2 Step 3 3. Connect the AC OUTPUT connections (AC plugs or terminal connections). (Step2) 4.
CPS7500PRO/CPS7500PIE Step 4 Step 5 5. Connect the batteries to the BATTERY INPUT. (Step4) WIRING FAULT LED will illuminate and make an audible alarm to indicate the wiring polarity is reversed. 6. If the battery box or the battery connection has a switch, please turn it on first. 7. Turn on the BATTERY SW. on the back of the machine (Step 5) 8. Turn on the Power Switch and switch the Output Selector to Normal on the front panel. The Power On Indicator and the LCD Module Display will blink 4 times.
CPS7500PRO /CPS7500PIE REPLACING BATTERY Replacing battery CAUTION! Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery. Battery service should only be done by qualified professionals. CAUTION! Use only the specified type and number of external batteries. Please see the technical specifications for replacement batteries. CAUTION! The battery may present a risk of electrical shock. Do not dispose of battery in a fire as it may explode.
CPS7500PRO/CPS7500PIE DEFINITIONS FOR ILLUMINATED LCD Definitions for illuminated LCD The LCD Display indicates a variety of EPS operational conditions. All descriptions apply when the EPS is plugged into an AC outlet and turned on or when the EPS is on battery. 1. INPUT VOLTAGE Meter: This meter measures the AC voltage that the EPS is receiving from the utility wall outlet.
CPS7500PRO /CPS7500PIE 10. LOAD CAPACITY Meter: This meter displays the approximate output load level (in 20% increments) of the EPS's battery outlets. EPS Status Inquiry and Functions Setup EPS status inquiry and functions setup 1. General Mode a. Press the “Display” button to check the status of the EPS. Item Input Voltage Unit V Output Voltage Output Frequency V Hz Load Load Capacity Kw % Battery Capacity Centigrade % Fahrenheit ℃ ℉ b. Press and hold the Display toggle for 4 seconds.
CPS7500PRO/CPS7500PIE Function description: AVR Dynamic Voltage Compensation works automatically based on the system voltage settings. d. Static Frequency Tolerance: There are 6 settings (1,2,4,6,8,10%), and the default setting is +/-10%. Function description: The settings may be adjusted to the quality of the electricity in use. e. Slew Rate (Dynamic Frequency Tolerance): There are 5 different settings (0.25,0.5,1,2,4 Hz/Sec). The default value is 4Hz/sec.
CPS7500PRO /CPS7500PIE FAULT WARNING DISPLAY AND ALARM Fault warning display and alarm 1. 2. :The machine shut down and the LCD display output voltage is zero. Over-Load Protection:The machine shut down and Over Load and FAULT Icon lights on the LCD Overheat Protection display. :The machine sounds long and rapid beep and Battery icon flashes. 3. Battery Missing 4.
CPS7500PRO/CPS7500PIE TROUBLESHOOTING Trouble shooting Problem Possible Cause Circuit breaker has tripped due to an overload. Outlet does not provide power to equipment. Batteries are discharged. Unit has been damaged by a surge or spike. The EPS will not turn on. Uncritical outlets have turned off automatically due to an overload. The on/off switch is designed to prevent the damage that rapidly turns it off and on. The unit is not connected to an AC outlet. The battery is worn out.
CPS7500PRO /CPS7500PIE TECHNICAL SPECIFICATIONS Technical specifications Model CPS7500PRO Capacity (VA) Capacity (Watts) Operation Technology AC Input CPS7500PIE 7500 5250 AVR ( Single Boost & Single Buck ) Input Voltage Range Input Frequency Range 140Vac – 300Vac 50/60 Hz +/- 5 Hz (auto sensing) AC Output Phase Single Phase Output Voltage Nominal Output Voltage Pure Sine Wave at 220Vac +/- 10% Configurable for 220 : 230 : 240Vac Battery Output Frequency Overload Protection 50 / 60 Hz +/- 1% On
CPS7500PRO/CPS7500PIE Scope and User Object The equipment use in low-voltage TN/IT distribution systems and intended to be installed in any operator accessible area. It specifies requirements to ensure safety for the operator and layman who come into contact with the equipment see above all information (page 1 to page 15).
CPS7500PRO/CPS7500PIE For more information, contact us at: CyberPower North America CyberPower Systems (USA), Inc. 4241 12th Avenue East Suite 400 Shakopee, MN 55379 Tel: 952-403-9500 Fax: 952-403-0009 Website: http://www.cyberpowersystems.com E-mail: sales@cyberpowersystems.com CyberPower Europe CyberPower Systems B.V. Flight Forum 3545,5657DW Eindhoven,The Netherlands Tel: +31 (0)40 2348170 Fax: +31 (0)40 2340314 Website: http://eu.cyberpowersystems.com/ E-mail: sales@cyberpower-eu.
FR Manuel d’utilisation CPS7500PRO/CPS7500PIE CyberPower North America CyberPower Systems (USA), Inc. 4241 12th Avenue East Suite 400 Shakopee, MN 55379 Tel: 952-403-9500 Fax: 952-403-0009 Website: http://www.cyberpowersystems.com E-mail: sales@cyberpowersystems.com CyberPower Europe CyberPower Systems B.V. Flight Forum 3545,5657DW Eindhoven,The Netherlands Tel: +31 (0)40 2348170 Fax: +31 (0)40 2340314 Website: http://eu.cyberpowersystems.com/ E-mail: sales@cyberpower-eu.
CPS7500PRO/CPS7500PIE AVERTISSEMENTS DE SECURITE IMPORTANTS Sety and EMC instruction Ce manuel contient d’importantes instructions de sécurité. Veuillez lire et suivre scrupuleusement toutes les instructions pendant l'installation et l'utilisation de l’appareil. Lisez ce manuel attentivement avant de déballer, d'installer ou d'utiliser votre Système Électrique de Secours (SES).
CPS7500PRO /CPS7500PIE ATTENTION ! Le SES doit être relié au dispositif de commutation d'urgence. NE PAS UTILISER SUR DES APPAREILS MEDICAUX OU DE SURVIE! Ne jamais utiliser ce type d’onduleur avec des appareils médicaux ou des appareils de maintient en vie du patient. NE PAS UILISER SUR OU A PROXIMITE D’AQUARIUMS! Afin de réduire les risques d’incendie ou de choc électrique, ne pas utiliser à proximité ou avec un aquarium. La condensation de l ‘aquarium pourrait entrainer la destruction de l’onduleur.
CPS7500PRO/CPS7500PIE INSTALLATION DE VOTRE SYSTEME EPS DEBALLAGE Inspectez l’UPS tout en consultant le bordereau d’expédition afin de vous assurer qu’aucune des pièces suivantes ne manque: 1 unité onduleur; 1 guide d'installation ; 1 manuel d'utilisation; 1 manuel installé de chargeur de batterie RÉGULATEUR DE TENSION AUTOMATIQUE (AVR) Le EPS peut stabiliser les incohérences de l'alimentation.
CPS7500PRO /CPS7500PIE secteur. Assurez-vous que votre équipement véhicule un courant de charge dans les limites de sécurité de l’appareil, (se référer aux spécifications techniques), puis allumez l'appareil. 5. Si une surcharge est détectée, une alarme sonore retentit et l'appareil émet un bip long. Pour corriger cela, mettez le SES hors tension et débranchez au moins un équipement des prises alimentées par la batterie. Patientez 10 secondes.
CPS7500PRO/CPS7500PIE OPERATIONS DE BASE BASIC OPERATION CPS7500PRO CPS7500PIE DESCRIPTION 1. Prises secteur CA Les gammes PRO/PIE ont deux prises à brancher à utilisation générale (R.-U. / Schuko / France) et une sortie par bornier pour les équipements connectés, ce qui assure un fonctionnement ininterrompu temporaire des équipements pendant une panne de courant. La sortie maxi de 1a est de 40A ; La sortie maxi de 1b est de 12A pour la prise R.-U., de 16A pour la prise Schuko / français.
CPS7500PRO /CPS7500PIE 6. Disjoncteur d'entrée Le disjoncteur sert à fournir une protection de l'entrée contre les surcharges et les pannes. 7. Disjoncteur de chargeur Limitez le courant de chargeur d'entrée pour empêcher dû endommagé par chargeur pour surcharger. 8. LED de défaut de câblage d'entrée batterie La LED de défaut de câblage d'entrée batterie s'allume et une alarme sonore retentit pour indiquer que la polarité du câblage est inversée. 9.
CPS7500PRO/CPS7500PIE GUIDE D'INSTALLATION Remarque : L'installation doit être effectuée par des professionnels. Étape 1 1. Retirez le couvercle à l'arrière de la machine. 2. Assurez-vous que les commutateurs SW POWER, le sélecteur de sortie, et SW BATTERIE sont éteints. (Étape 1) Le SES ne fonctionne pas si le sélecteur de sortie est sur OFF. Assurez-vous que le sélecteur est sur la position Normal après toutes les procédures d'installation. Étape 2 Étape 3 3.
CPS7500PRO /CPS7500PIE Étape 4 Étape 5 5. Connectez les batteries sur l'ENTRÉE BATTERIE. (Étape 4) La LED DE DÉFAUT DE CÂBLAGE s'allume et une alarme sonore retentit pour indiquer que la polarité du câblage est inversée. 6. Si la boîte de la batterie ou le branchement de la batterie dispose d'un interrupteur, veuillez l'allumer en premier lieu. 7. Allumez le COMMUTATEUR BATTERIE au dos de la machine (Étape 5) Étape 6 8.
CPS7500PRO/CPS7500PIE REMPLACEMENT DE LA BATTERIE Replacing the battery ATTENTION ! Lisez et suivez les IMPORTANTES INSTRUCTIONS DE SÉCURITÉ avant de toucher à la batterie. Remplacez la batterie sous la supervision d’un personnel qualifié. ATTENTION ! La batterie peut être la source de risques d’électrocution. Ne jetez pas la batterie dans un feu car elle peut exploser. Respectez les réglementations locales concernant l’élimination appropriée des batteries.
CPS7500PRO /CPS7500PIE DEFINITIONS DES VOYANTS DE L’ECRAN NUMERIQUE Definitions for illuminated LCD L'écran LCD indique une variété de conditions opérationnelles du SES. Toutes les descriptions s'appliquent lorsque le SES est branché sur une prise secteur et allumé, ou lorsque le SES est sur batterie. 1. Mesure de la tension d'entrée : Cet instrument mesure la tension secteur de la prise murale. La mesure de tension d'ENTRÉE sert à identifier les informations sur la tension d'entrée.
CPS7500PRO/CPS7500PIE FONCTIONS DE CONFIGURATION LCD EPS status inquiry and functions setup 1. Mode général a. Appuyez sur le bouton "Bascule affichage" pour vérifier l'état de l'onduleur : Item Unit Tension d'entrée Tension de sortie V V Output Frequency Load Hz Kw Capacité de charge Capacité de la batterie % % Centigrade Fahrenheit ℃ ℉ b.
CPS7500PRO /CPS7500PIE e. Vitesse de montée : Aussi connu sous le nom de Tolérance de fréquence dynamique. Il y a 5 réglages différents (0,25,0,5,1,2,4 Hz/Sec). La valeur par défaut est 4Hz/sec. Description fonctionnelle : "Vitesse de montée" indique la tolérance d'un dispositif à accepter la variance de fréquence. Une "vitesse de montée" plus faible donne une tolérance moindre, mais une meilleure protection de la charge connectée et vice-versa. f.
CPS7500PRO/CPS7500PIE AFFICHAGE ET ALARME D'AVERTISSEMENT DE PANNE 1. Protection contre la surchauffe : La machine s'arrête et l'affichage de la tension de sortie indique zéro. 2. Protection contre la surcharge : La machine s'arrête et les icônes Surcharge et PANNE s'allument sur l'écran LCD. 3. Batterie manquante : La machine émet un bip sonore long et un rapide, et l'icône de batterie clignote. 4.
CPS7500PRO /CPS7500PIE PROBLÈMES ET SOLUTIONS T Problème Cause possible Le disjoncteur a sauté en raison d'une surcharge. La sortie ne délivre pas de puissance à l'équipement. L'onduleur ne s'allume pas. Les batteries sont déchargées L'unité a été endommagée par une surtension ou un pic. Les sorties non critiques ont été éteintes automatiquement en raison d'une surcharge. Le bouton marche/arrêt est destiné à prévenir les dommages dus à une mise hors et sous tension rapide.
CPS7500PRO/CPS7500PIE CARACTÉRISTIQUES TECHNIQUES Technical specifications Modèle Puissance (VA) Puissance (Watts) Technologie de fonctionnement AC Entrée Connexions d'entrée Fréquence d’entrée AC Sortie Nombre de phases Tension de sortie à la batterie Tension nominale de sortie Fréquence de sortie à la batterie Protection contre les surcharges Temps de transfert Prises de sortie CPS7500PIE CSP7500PRO 7500 5250 RAT (Boost double et buck unique) 140Vac – 300Vac 50/60 Hz +/- 5 Hz (auto sensing) Monophasé
CPS7500PRO/CPS7500PIE Des informations complémentaires relatives aux Problèmes et Solutions se trouve dans la section “Support” du site eu.cyberpowersystems.com Pour plus d’informations, visitez eu.cyberpowersystems.com ou contactez CyberPower Systems (USA) 4241 12th Avenue East Suite 400 Shakopee, MN 55379 Tel: 952-403-9500 Fax: 952-403-0009 Website: http://www.cyberpowersystems.com E-mail: sales@cyberpowersystems.com CyberPower Systems B.V.