On Windows, go to Start > Control Panel > Add or Remove Programs. Click the Change/Remove button of
PowerPanel
®
Business Edition to uninstall the program.
On Linux and VMware ESXi, only PowerPanel
®
Business Edition Client can be installed. The default installation
directory is /usr/local/ppbe on the Linux platforms and /opt/ppbe on VMware ESXi. Execute the uninstall.sh
command in the installation directory to uninstall the program.
10. How can I get a notice when a power condition has cleared?
When a power condition is clear, it will broadcast a notification and also run the command file. A custom script
can be created for events. The script can utilize the environment variable EVENT_STAGE to compare the key
OCCUR to identify an event that has occurred or FINISH to identify an event that has cleared.
11. What network protocol is used in PowerPanel
®
Business Edition?
SNMP is used on communications between Client, Center, PDU or UPS with remote management card. HTTP
and HTTPS are used between the Agent and the Client.
12. What the network ports are used by PowerPanel
®
Business Edition?
Port 3052 (UDP/TCP), port 53568 (TCP), port 161(UDP), port 162 (UDP) and port 53566(UDP)
13. I try to set the Client to establish to communication with one of PDUs. How do I identify the targeted
device IP?
Refer to the Easy-to-Setup Device IP for details.
14. How do I ensure that the SNMP settings between the Client and UPS/PDU/ATS are properly setup?
To receive the trap notification from the UPS/PDU/ATS all the time, follow steps to verify the SNMP settings:
Open the Network/Trap Notification page on the UPS/PDU/ATS web and the Security/Authentication page
on the Client.
Confirm that the IP address of the Client can be found on the Network/Trap Notification page of the
UPS/PDU/ATS web. If the IP address can be searched, skip the step 3.
If the IP address of the Client could not be found, click the Trap Receiver shortcut of the Network/Trap
Notification page to enter the Trap Configuration page. Enter the required data to add a new trap receiver.
If the IP address of the Client could be found, verify the SNMP settings are matched.
15. How do I determine that if my computer is using hibernation or not?
If the operating system is Windows 2000, Windows XP or Windows Server 2003, please follow the below steps
to enable the hibernation:
Open Power Options in the Control Panel. (Go to Start > Control Panel > Power Options.)
Click the Hibernate tab, and then select the Enable hibernate support option. Click the OK button to close the
Power Options dialog box. The hibernation has been enabled. If the tab is not available, your computer
doesn’t support this hibernation.