User`s manual
CYMOD 4531
•
57
Special Commands
Read Command Leading Code
Setting
~(Addr)0
Change Command Leading
Code Setting
~(Addr)10(C1)(C2)(C3)
(C4)(C5)(C6)
Set Host Watchdog / Safety Value ~(Addr)2(Flag)(TimeOut) (SafeValue)
Read Host WatchDog / Safe
Value
~(Addr)3
Host is OK ~**
5.4.3 Set Configuration
@Description
Configure the basic setting about address ID, baud rate, and checksum.
@Syntax
%(OldAddr)(NewAddr)(TypeCode)(BaudRate)(DataFlag)<CR>
% Command leading code.
(1-character)
(OldAddr) Original address ID. The default address ID of
a brand new module is 01. The value range of
address ID is 00 to FF in hexadecimal.
(2-character)
(NewAddr) New address ID, if you don’t want to change
address ID, let new address ID equal the
old one. (2-character)
(TypeCode) Type Code is fixed 40H. (2-character)
(BaudRate) Communication baud rate, refer to Table 3-1 for
details. The first character is for RS-232, the
second character is for RS422/485.
(2-character)
(DataFlag) Define check-sum status, refer to Table3-2 for
details. (4-character, WXYZ) WX is for module
system setting. YZ is for RS-232 configuration.
W. bit 3 0 Normal addressable mode (*Default Setting)
1 Non-addressable mode (CM 4520 mode)
W. bit 2 0 Disable checksum (*Default Setting)
1 Enable checksum
W. bit 1 0 RS-422 interface