CYMOD 4531
1 RS-485 interface (*Default Setting)
W. bit 0 Dont care, set to 0
X. bit 3 Dont care, set to 0
X. bit 2 Dont care, set to 0
X. bit 1 Dont care, set to 0
X. bit 0 0 Dont append <CR> in output string
1 Append <CR> in output string(*Default
Setting)
Y. bit 3 Dont care, set to 0
Y. bit 2 Dont care, set to 0
Y. bit 1 Dont care, set to 0
Y. bit 0 0 Odd parity (*Default Setting)
1 Even parity
Z. bit 3 0 Non-parity mode (*DefaultSetting)
1 Parity mode
Z. bit 2 0 One stop bit (*Default Setting)
1 Two stop bit
Z. bit 1 0 00 5 data bit format
01 6 data bit format
10 7 data bit format
11 8 data bit format
@Response
!(Addr)<CR>
or
?(Addr)<CR>
(Addr) Address ID.
! Command is valid.
? Command is invalid. Invalid parameter values,
When you wanted to change the setting without
grounding the DEFAULT* pin.
Note :When you want to change the checksum or baud rate or
DataFlag, the DEFAULT* pin should be grounded first.