CYDAS UDR Library User’s Guide Analog Input Boards - CYDAS 1602, CYDAS 1202 & CYDAS 100x Series
40
CYDAS 1602, CYDAS 1202 & CYDAS 100x Series
Analog input
Analog input functions and methods supported
UDR:
cbAIn(), cbAInScan(), cbATrig(), cbAPretrig(), cbFileAInScan(),
cbFilePretrig()
UDR for .NET: AIn(), AInScan(), ATrig(), APretrig(), FileAInScan(), FilePretrig()
Analog input argument values
Options BACKGROUND, CONTINUOUS, EXTCLOCK, CONVERTDATA, SINGLEIO, BLOCKIO,
BURSTMODE, EXTTRIGGER
HighChan
0 to 15 in single-ended mode, 0 to 7 in differential mode
Rate CYDAS 1602DAP, CYDAS 1202DAP, CYDAS 1202P
Up to 330000
CYDAS 1000P
Up to 250000
CYDAS 1602HRDAP, CYDAS 1002DAP
Up to 200000
CYDAS 1001DAP
Up to 150000
Range CYDAS 1602DAP, CYDAS 1602HRDAP, CYDAS 1202DAP, CYDAS 1202P,
CYDAS 1002DAP, CYDAS 1000P
BIP10VOLTS UNI10VOLTS
BIP5VOLTS UNI5VOLTS
BIP2PT5VOLTS UNI2PT5VOLTS
BIP1PT25VOLTS UNI1PT25VOLTS
CYDAS 1001DAP
BIP10VOLTS UNI10VOLTS
BIP1VOLTS UNI1VOLTS
BIPPT1VOLTS UNIPT1VOLTS
BIPPT01VOLTS UNIPT01VOLTS
Analog output
Excludes CYDAS 1202P
Analog output functions and methods supported
UDR:
cbAOut(), cbAOutScan()
UDR for .NET: AOut(), AOutScan()
Analog output argument values
Options SIMULTANEOUS
For CYDAS 1602 Series, the following argument values are also valid:
BACKGROUND, CONTINUOUS, EXTCLOCK
HighChan
0 to 1
Rate CYDAS 1602HRDAP CYDAS 1602DAP All others
Up to 100000 Up to 250000 Ignored