User`s manual
CYDAS UDR Library User’s Guide Analog Input Boards - CYDAS 1602HDP and CYDAS 16JRHRU Series
44
CYDAS 1602HDP and CYDAS 16JRHRU Series
Analog input
Analog input functions and methods supported
UDR:
cbAIn(), cbAInScan(),cbFileAInScan(), cbATrig()
UDR for .NET: AIn(), AInScan(),FileAInScan(),ATrig()
Analog input argument values
Options BACKGROUND, CONTINUOUS, EXTCLOCK, CONVERTDATA, SINGLEIO, BLOCKIO,
BURSTMODE, EXTTRIGGER
HighChan
0 to 15 in single-ended mode, 0 to 7 in differential mode
Rate 100000
Range BIP10VOLTS UNI10VOLTS
BIP5VOLTS UNI5VOLTS
BIP2PT5VOLTS UNI2PT5VOLTS
BIP1PT25VOLTS UNI1PT25VOLTS
Analog output (CYDAS 1602HDP only)
Analog output functions and methods supported
UDR:
cbAOut(), cbAOutScan()
UDR for .NET:
AOut(), AOutScan()
Analog output argument values
Options Ignored
HighChan 1 max
Count 2
Rate Ignored
Range Ignored
DataValue 0 to 4095
Digital I/O
Digital I/O functions and methods supported
UDR:
cbDOut(), cbDIn(), cbDBitIn(), cbDBitOut()
UDR for .NET: DOut(), DIn(), DBitIn(), DBitOut()
The CYDAS 1602HDP also supports:
UDR:
cbDConfigPort()
UDR for .NET:
DConfigPort()