User`s manual

CYDAS UDR Library User’s Guide Analog Input Boards - CYDAS 1400 and CYDAS 1600 Series
64
CYDAS 1400 and CYDAS 1600 Series
Analog Input
Analog input functions and methods supported
UDR:
cbAIn(), cbAInScan(), cbATrig(), cbFileAInScan()
UDR for .NET: AIn(), AInScan(), ATrig(),FileAInScan()
Analog input argument values
Options BACKGROUND, CONTINUOUS, EXTCLOCK, CONVERTDATA, SINGLEIO, DMAIO, BURSTMODE,
EXTTRIGGER
For CYDAS 1600, the following argument values are also valid:
DTCONNECT, EXTMEMORY.
HighChan 0 to 15 in single-ended mode, 0 to 7 in differential mode
Rate CYDAS 1401, CYDAS 1402, CYDAS 1601, CYDAS 1602
160000
CYDAS 1602HR, CYDAS 1402HR
100000
CYDAS 1401, CYDAS 1402, CYDAS 1601, CYDAS 1602 to external memory
330000
Range CYDAS 1402, CYDAS 1602, CYDAS 1402HR and CYDAS 1602HR
BIP10VOLTS UNI10VOLTS
BIP5VOLTS UNI5VOLTS
BIP2PT5VOLTS UNI2PT5VOLTS
BIP1PT25VOLTS UNI1PT25VOLTS
CYDAS 1401 and CYDAS 1601
BIP10VOLTS UNI10VOLTS
BIP1VOLTS UNI1VOLTS
BIPPT1VOLTS UNIPT1VOLTS
BIPPT01VOLTS UNIPT01VOLTS
Analog output (CYDAS 1600 series only)
Analog output functions and methods supported
UDR:
cbAOut(), cbAOutScan()
UDR for .NET: AOut(), AOutScan()
Analog output argument values
Options SIMULTANEOUS
HighChan
1 max
Count 2 max
Rate Ignored
Pacing Software pacing only
Range Analog output gain is not programmable, so the Range argument is ignored.
DataValue 0 to 4095