User`s manual

CYDAS UDR Library User’s Guide Analog Input Boards - CYDAS 48
67
CYDAS 48
Analog Input
Analog input functions and methods supported
UDR:
cbAIn(), cbAInScan(), cbATrig(), cbFileAInScan()
UDR for .NET: AIn(), AInScan(), ATrig(), FileAInScan()
Analog input argument values
Options CONVERTDATA
HighChan 47 (23 differential)
Rate This board does not have a timer, so the Rate argument to the analog scanning
functions is ignored.
Range The board may be configured with a jumper for either voltage or current input.
In voltage mode
BIP10VOLTS UNI10VOLTS
BIP5VOLTS UNI5VOLTS
BIP2PT5VOLTS UNI2PT5VOLTS
BIP1PT25VOLTS UNI1PT25VOLTS
BIPPT625VOLTS
In current mode
MA4TO20 MA2TO10
MA1TO5 MAPT5TO2PT5
Analog output
Analog output functions and methods supported
The CYDAS 48 board does not support any of the analog output functions.
Digital I/O
Digital I/O functions and methods supported
The CYDAS 48 does not support any of the digital I/O functions.
Counter I/O
Counter functions and methods supported
The CYDAS 48 does not support any of the counter I/O functions.