Service manual
Cybex 600T Treadmill Service
Manual
E-Stop
Port
CSAFE
Port
Contact Heart
Rate Port
Polar
Port
Figure 16
Heart Rate Board
Polar
Board
Front Sensor
Plate
Page 5-20
Tools Required
• Phillips head screwdriver
NOTE: This procedure will cover the heart rate board and handset board.
1. Turn
the
power
off.
A.
Turn
the main power switch
in
the front panel
to
the off (0) position.
B. Unplug the treadmill from the power outlet.
2.
Remove
the
console
back.
A. Remove the eleven Phillips head screws on the console back. Leave the
top
screw
which holds the accessory holder
in
place. The
top
screw will keep the accessory
holder
in
place on the console back. Set the console back and screws aside. See
Figure 15.