Service manual

Cybex Arc Trainer 610A Service Manual
Service
Page 4-3
LED Functions
LEDs are used to indicate the status of many of the unit inputs. After entering Test Mode refer to the
following list to check that these LEDs are functioning properly:
Heart LED - Blinks on blue with every signal from the contact heart rate receiver and red for wireless
signals (Polar).
Weight LED - Blinks on when CSAFE data is being received.
Level LED - Blinks on when CSAFE data is being transmitted.
Lower Left Window - The numbers indicate actual elevation. The decimal point before the numbers
shows the activation of the level 3 position switch in the elevation motor (on above level 3). If dashes
are shown in the display, the unit is either above or below the level 3 position switch, requiring it to be
manually run through the switch to begin indicating actual elevation.
Lower Right Window - The numbers indicate resistance (0-100). The right most decimal point
indicates the pulses from the speed sensor.
Key Functions
While in Test Mode press the following keys for desired information:
Hill Interval key - Lights all of the LEDs for a short period of time.
Weight Loss key - Lights only the columns.
Strength key - Lights only the rows.
Incline - Run elevation motor up.
Incline - Run elevation motor down.
Resistance + (plus) - Run resistance up.
Resistance - (minus) - Run resistance down.
Distance - Press once for odometer information (DST) to appear in the speed window.
Press again for hour meter information (HRS) to appear in the speed window.
Press three times for number of starts information (USES) to appear in the speed window.
Press four times for number of positions the elevation (ELV) has ever moved. Example: if a user runs
the elevation from 2 to 3, 1 position is added to this number.
Strides Per Minute - Displays and cycles through error log. Up to 10 errors can be stored.
Scan - Clears error log when pressed twice while in error log mode.
Mets - Displays the torque in ft-lbs, (relative to LOAD).
Calories - Displays brake pulse width (PWM) value (the value of brake load in A/D counts). The number
range is relative to brake current and goes from 0-200.
Enter - Required to save setup values
.