OWNER’S MANUAL FOR HOUSEHOLD USE ONLY Please read this document carefully before installing and/or using your vacuum cleaning system.
IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precautions should always be followed, including the following. Read all instructions before using this appliance. WARNING – To reduce the risk of fire, electric shock, or injury : 1. Do not leave appliance when plugged in. Unplug from outlet when not in use and before maintenace. 2. Do not use outdoors or on wet surfaces. 3. Do not allow to be used as a toy. Close attention is necessary when used by or near children or infirm persons.
Table of Contents Preface Schematic – Axess, GS110 & GS111 models Schematic – E & GS Series Schematic – DL & GX series Unit Installation 6 6 7 8 9 INSTALLATION Dos & Don’ts – Installing conduits Dos & Don’ts – Installing Inlets Muffler Installation Electric Connections Grounding Instructions Low Voltage Connections 10 12 13 15 16 17 OPERATING INSTRUCTIONS Hose Hook-up & Inlets Progressive Start Automatic Stop LED Indicator DataSync Monitor DataSync Hose Cyclo Vac Attachments 18 19 19 19 20 21 22 MAINT
Preface Your new Cyclo Vac central vacuum system was designed and manufactured in Blainville, Quebec, by the largest central vacuum cleaner manufacturer in Canada. With over forty-five years of experience in the field, we provide a high-quality, state-of-the-art product, and guarantee your complete satisfaction. Our extensive network of qualified professionals ensures first quality service near you. Contact us for the location of the Cyclo Vac authorized dealer in your area, or visit our website: www.
Schematic E & GS SERIES 1. 2. 3. 4. 5. 6. 7. Circuit breaker Low Voltage Connector & LED Serial Number Air Intake Muffler Carbon Dust Filter (GS310 & 311 models only) Air Exhaust min. 30 cm (12") With muffler turned down, min. 30 cm (12") 6 5 1 2 3 7 4 min. 30 cm (12") min. 30 cm (12") min.
Schematic DL & GX SERIES 1. 2. 3. 4. 5. 6. 7. 8. Circuit breaker Low Voltage Connector Serial Number DataSync Monitor - LCD Screen Air Intake Muffler Carbon Dust Filter Air Exhaust min. 30 cm (12") With muffler turned down, min. 30 cm (12") 7 6 1 2 3 4 8 5 min. 30 cm (12") min. 30 cm (12") min.
Unit Installation Using the mounting plate provided with your vacuum cleaner, secure the unit to the wall (figure 1), at a height allowing easy access to change the bag (see pages 6 to 8). figure 1 The connections to the piping system will require some basic tools: a mitre box and small saw or a pipe cutter (figure 2). See pages 10 and 11 for general instructions pertaining to the preparation of PVC pipes.
Dos & Don’ts INSTALLING THE PIPING 10 Installation
Dos & Don’ts Installation 11
Dos & Don’ts INSTALLING INLETS When installing your vacuum inlets, we recommend that the principle of electric polarity be taken into account. Ensure that the wire connected onto contact A on inlet 1 is the same as that connected to contact A on inlet 2, and so on. Do not cross, reverse or interchange wires.
Muffler Installation 1. Insert the rubber coupling on the vacuum air exhaust. 2. Using a Phillips screwdriver, tighten the clamp collar to ensure adequate sealing. 3. Insert the 90° elbow into the rubber coupling, and tighten the clamp collar as per instructions in step 2. 4. Apply ABS glue to the 90° elbow and insert muffler. AXESS - GS110 & GS111 MODELS A. B. C. D. C B Rubber coupling 90° elbow Muffler Air Exhaust A D Glue not included.
Muffler Installation 5010 - 5011 (1 muffler) & 7010 - 7011 (2 mufflers) MODELS WARNING Your central vacuum is a high performance unit, equipped with two high output motors, whose maximum performance requires a specific installation: 7010/7011 Included 5010/5011 2x r øDN 1x r DN 2x 1x r $POOFDUJPO UP B WPMUT PVUMFU (Type Nema 6/15 in North America) r *OTUBMMBUJPO JO B XFMM WFOUJMBUFE SPPN of at least 75 square feet (7 m2) r &YIBVTU DPOOFDUJPO UP NFUBM QJQJOH system, with
Electric Connections There should be an electric outlet within 1 meter (3 feet) of your central vacuum unit. Once the appliance is installed in a suitable location, connect your central unit to an electric outlet on a EFEJDBUFE HSPVOEFE DJSDVJU Do not use extension cords or modify the length of your vacuum cleaner’s power cord.
Grounding Instructions This appliance must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord that has an equipment-grounding conductor and grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. No adaptor should be used with this appliance.
Low Voltage Connections Connect the low voltage wires to the low voltage inlet on your unit. To do so: 1. 2. 3. 4. 5. Strip wires over 1 cm (½ inch) (figure 5). Gently press on the toggle to open the connector (figure 6). Insert stripped wire (figure 7). Release toggle to secure wire in connector (figure 8). Repeat for second wire. To disconnect: 1. Gently press on the toggle to open the connector. 2. Remove low voltage wire from connector.
Hose Hook-up & Inlets Before operating your central vacuum… Please verify that your central vacuum is properly connected to the piping system, and to a grounded electrical outlet, and that the low voltage wires are connected to the unit (see pages 9 to 17).
Progressive Start (DL & GX Series) Each DL & GX model is equipped with a special module allowing for a smooth and gradual start-up of the vacuum system, to prolong motor durability. Automatic Stop (Except Axess model) In case you’ve forgotten to turn off your vacuum, or it’s been turned on by mistake, your vacuum system wil automatically shut off after one hour of uninterrupted use.
DataSync Monitor (DL & GX Series) Your central vacuum unit is equipped with an electronic timing device that will recommend proper maintenance of your vacuum system. These signals are only suggestions and will do not indicate a problem with your vacuum system. They will not stop or hinder the use of the vacuum.
DataSync Hose (DL & GX Series) The light emitting diodes on the DataSync hose will signal, by flashing, that it is time to change the bag or empty the canister, and even when maintenance is required. They do not indicate a problem with the vacuum system, and will not hinder or stop the use of the vacuum power unit.
Cyclo Vac Attachments 07"- %645*/( #364) Use just about anywhere : on lamps & lamp shades, blinds, shelves, and decorative trims 61)0-45&3: #364) With removable bristles, use to clean all upholstered furniture such as sofas, chairs, and mattresses. $3&7*$& 500Use in narrow spaces, nooks and crannies, such as heating ducts, and space between sofa cushions, and window panes. '-003 #364) Use on all types of floor: hardwood, ceramic or even small carpets or rugs.
Cyclo Vac Attachments )04& )0-%&3 In addition to conveniently holding your hose, it is specially designed to allow the storage of your floor brush on the telescopic wand, without crushing the brush bristles. 5&-&4$01*$ 8"/% Easily adjusted to the desired height. Simply press the button, then slide the wand to the desired length, and release the button to lock the wand into position. Convenient button-lock mechanism prevents the wand from slipping off the hose handle. push button here "55"$).
Motor Please note that $ZDMP 7BD NPUPST EP OPU SFRVJSF MVCSJDBUJPO. Each motor contains two carbon brushes that will wear normally, and may eventually require replacement. For warranty purposes, replacement should be done by an authorized dealer. Brush life is affected by hours of use, frequency of start-ups and shut-downs, humidity, altitude, and temperature. In order to avoid damage to the unit’s motor, brushes should be replaced before they are completely worn-out.
Dirt Receptacle (E & DL Series) Occasional maintenance of the dirt receptacle is necessary to ensure constant, lasting performance. We recommend that it be emptied at least every season, depending on frequency of use. To empty the dust receptacle, disconnect your vacuum cleaner from its power source. Then, release the two clamps and empty the recipient. Reseal the receptacle in place.
Filters (E & DL Series) Regular maintenance of the filtration system is recommended to ensure maximum performance of your central vacuum . Your Cyclo Vac central vacuum is equipped with two filters. The anti-clogging filter (thin fabric) stops the larger particles, and the Cyclofiltre (thick fabric) catches the microscopic particles. The Cyclofiltre is treated with Ultra-Fresh* to prevent the growth of mold, fungus and bacteria.
Electrostatic Bag (GS & GX Series) Replace the bag when full. Frequency will depend on use of the unit. For the GX series,the DataSync monitor will indicate when to change the bag. These indications are provided by an electronic timing board, only as a reference guide. 1. To access the bag, unlatch the two clips and remove the dust receptacle (figure 16). figure 16 2. Remove the used bag and seal bag opening (adhesive seal provided on each bag). Discard used bag. 3.
Disposable Bag & Filter (Axess, GS110 & GS111 models) Replace the bag when full. Frequency will depend on the use of the unit. 1. To access bag, remove the power unit top cover. 2. Remove the used bag and seal bag opening (adhesive seal provided on each bag). Discard used bag. 3. Install the new bag, ensuring the tabs on the bag adaptor are aligned with the slots in the bag collar (figure 19). àHVSF tabs on bag adaptator retention ring 4.
General Information If the vacuum unit does not work, check the fuse or breaker on the unit and/or in the electrical panel of your home, and replace any defective part(s) as deemed necessary. Please verify that the unit has been installed properly, according to the instructions in this manual. Your vacuum cleaning system is designed to collect everyday dry matter (dust). It is approved by authorized testing agencies for dry use only. Do not use on wet surfaces.
Troubleshooting 30 PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Decrease in suction strength Dirt recipient/Bag is full Empty dirt recipient / change bag (see pages 25 to 28). Dirt recipient is not properly attached Check clamps and dirt recipient are aligned. Filters need cleaning / replacing Remove, shake and/or wash filters or replace them (depending on model) before reinstalling them in the unit (see page 26).
Troubleshooting PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Decrease in suction strength (cont.) Blocked hose Plug the handle end of the hose into the suction inlet, thus reversing the suction in the hose. Cover the gap around the handle, to ensure suitable suction strength, and ensure contact with inlet contacts to start the unit. This should clear the hose Obstruction in the piping system Remove the screw from the air intake connector, to free the central vacuum unit from the piping system.
Troubleshooting PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Vacuum will not start The electrical power is not connected properly Ensure that the power cord is plugged into a dedicated grounded electrical outlet, according to specifications on pages 15 and 16. Low voltage wire is not connected properly Verify the low voltage wires, make sure they are properly inserted into the low voltage inlet, as per instructions on page 17.
Troubleshooting PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Vacuum will not stop Hose improperly inserted Ensure that the hose end into vacuum inlet is properly placed in the vacuum inlet: the tab on the hose should fit into the slots of the inlet, to ensure adequate contacts for the hose switch to function (see page 18).
Warranty Information 5IJT XBSSBOUZ JT WBMJE GPS EPNFTUJD VTF POMZ -*.*5&% -*'&5*.& 8"33"/5: Your Cyclo Vac vacuum system is protected by a lifetime warranty. We guarantee that the unit canister will be exempt of any material or manufacturing defect. This warranty is valid from the date of purchase, for as long as you are the original owner, and the system remains at its original place of installation.
Warranty Information 5)3&& :&"3 8"33"/5: 0/ $:$-0 7"$ 3&$0..&/%&% "55"$).&/54 All Cyclo Vac recommended attachments* are guaranteed for three years, subject to certain conditions. If during this three year period, an accessory presents a manufacturing defect, return it to the nearest authorized Cyclo Vac service center along with a copy of your invoice (clearly indicating the attachments purchased), and we will repair or replace the part according to the conditions of the warranty.
WEEE Directive *.1035"/5 &/7*30/.&/5"- */'03."5*0/ m &6301&"/ &$0/0.*$ "3&" 0/-: This appliance has been assessed in accordance with the European Parliament Directive on Waste Electrical and Electronic Equipment, usually referred to as the WEEE Directive. The WEEE Directive requires that the appliance be disposed of at the end of its useful life in an environmentally responsible manner.
Notes
Notes
WWW.CYCLOVAC.COM Head Office CANADA 3, rue Marcel-Ayotte Blainville (Québec) J7C 5L7 5FM r 'BY info@cyclovac.com 1 888 77CYCLO Distribution Centers EUROPE 16, rue du Stade 44170 Treffieux France 5FM r 'BY PRINTED IN CANADA IMPMOD925 - NOV’09 info@cyclovac.