Self-Cleaning Range Hoods Undermount Range Hoods Models: NA940D, NA930C/R, CY1000C/R, CY2080R, CY1011R, CLC11, CYS1000R, CY3000R, NA330R, NA830R, NA430R, CLN30 Installation and Operation Instructions Please read all instructions before installing and operating. All wiring and installation must be in accordance with CEC, NEC and local electrical codes.
Cyclone Undermount Installation - English
IMPORTANT SAFETY INSTRUCTIONS WARNING • • • This appliance must be installed by a qualified technician. The manufacturer declines all responsibilities in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence, and the warranty of the unit automatically expires due to improper installation and maintenance.
CONTENTS 4 Important Safety Instructions 3 Damage Inspection 5 Ducting 5 Mounting Heights and Clearance 6 Wiring Installation 6 Undermount Installation - Tools and Materials Required 7 Undermount Installation - Parts supplied 7 Undermount Hood Installation 8 Undermount Hoods Specifications 10 Troubleshooting 11 Maintenance 12 Control Panel 13 Cyclone Range Hoods Limited Warranty 14 Cyclone Undermount Installation - English
DAMAGE INSPECTION • • • • Please fully inspect unit for damage before installation. If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or replacement. If the unit is damaged by the customer, repair or replacement is the responsibility of the customer. If the unit is damaged by the installer (if other than the customer), repair of replacement must be made by arrangement between customer and installer.
MOUNTING HEIGHTS AND CLEARANCE WARNING • The hood should be installed at 28” minimum above the cooking surface. If pairing your range hood with a gas stove minimum mounting height must be 30” above the cooking surface. Minimum mount height between range top to hood bottom should be no less than 28” for electric or ceramic stoves, and no less than 30” for gas stoves. The maximum mount height should be no more than 36”. The hood must be installed at the correct mounting height.
UNDERMOUNT INSTALLATION - TOOLS AND MATERIALS REQUIRED • • • • • • • • • • Electrical drill or ratchet driver Phillips screwdriver #2 or driver bit Straight blade screwdriver Wire stripper or cutter Tape measure Electrical supplies for wiring (i.e.
UNDERMOUNT HOOD INSTALLATION WARNING • Turn off power circuit at the service panel before wiring this unit. All electrical work must be done by a qualified electrician in accordance with all applicable codes and standards. This range hood must be properly grounded. • CAUTION • At least two installers are required due to the weight and size of the hood. Baffle Removal for NA330R: Figure 1a. Preparation for Installation 1. Unpack range hood and check contents.
Preparation for Vent and Exhaust Duct Connection 1. 2. 3. To connect a rectangular vent to a round exhaust duct (or vice versa), use a connecting duct and adapter. The round vent of a Cyclone Range Hood is 6” diameter. If the round exhaust duct is not 6” diameter, a connecting duct is necessary to accommodate the different size. If the exhaust duct is less than 6” diameter, the efficiency of your Cyclone Range Hood will be reduced and the warranty may be voided.
UNDERMOUNT HOODS SPECIFICATIONS NA930C/NA930R/ NA940D CY1000C/CY1000R/ CY1011R/CLC11/CY2080R CY3000R CYS1000R NA330R/NA830R/ NA430R/CLN30 SIZE 30” 30” 30” 24”/30” 30”/36” MAX. CUBIC FEET/METER (CFM) 680 680 CLC11 - 580 CY2080R - 300 680 300 680 CLN30 - 580 MAX.
TROUBLESHOOTING For additional service inquiries, contact Cyclone servicing department at 1-888-293-5662 or Service@CycloneRangeHoods.com ISSUE CAUSE Unit doesn’t work after 1. installation. 1. Ensure power is ON for the circuit breaker and unit. 2. The power line and the cable locking connector 2. are not connected properly. Check the power connection with the unit is connected properly. 3. The control panel or motherboard is defective (CY3000R/NA330R/NA830R/NA430R/ CLN30). 3.
MAINTENANCE For a complete description of our maintenance and operating instructions you may visit us online at www.CycloneRangeHoods.com to download your model’s Use and Care Guide. Due to the fact that we are always striving to improve our products and take advantage of advances in technology, there may be slight variations in your product. WARNING • Always switch off power and unplug before cleaning and maintenance.
CONTROL PANEL Model: NA330R/NA830R/NA430R/CLN30(above) CY3000R (below) The unit is controlled by a digital touch switch. Light Power LOW speed Timer/24 Hour Clock HIGH speed Power Model: NA930C/NA930R/NA940D/CY1000C/ CY1000R/CY2080R/CY1011R/CLC11 The unit is controlled by rocker switches. The fan and light are each controlled by a rocker switch. The fan switch has three positions: HIGH, LOW and OFF. The light switch has two positions, ON and OFF.
CYCLONE RANGE HOODS LIMITED WARRANTY Cyclone Range Hoods Inc. (hereunder called “The Company”) provides a warranty that its products are free from defects in workmanship and materials for a period of two (2) years from the date of purchase. This warranty includes in-home service (where applicable) for the first year and workshop service for the second year. During that time period, The Company will, at the Company’s option, repair or replace without charge any parts or complete unit found to be defective.