Self-Cleaning Range Hoods Insert Range Hoods Models: BX212, BX215, BX155, BX600, BX360, CLX60, SS130 Installation and Operation Instructions Please read all instructions before installing and operating. All wiring and installation must be in accordance with CEC, NEC and local electrical codes.
Cyclone Insert Installation - English
IMPORTANT SAFETY INSTRUCTIONS Please read all instructions before installing and operating. Model specifications may vary, please check our website for the most up to date specifications. WARNING • • • This appliance must be installed by a qualified technician. The manufacturer declines all responsibilities in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product.
CONTENTS 4 Important Safety Instructions 3 Damage Inspection 5 Ducting 5 Mounting Heights and Clearance 6 Wiring Installation 6 Tools and Materials Required 7 SS130 - Parts supplied 8 SS130 Insert Hood Installation 9 SS130 - Installation Cutout Templates 10 BX155/BX212/BX215 - Parts supplied 11 BX212/BX215 Insert Hood Installation 12 BX155 Insert Hood Installation 13 BX155/BX212/BX215 - Installation Cutout Templates 14 BX600/BX360/CLX60 - Parts supplied 15 BX600/B
DAMAGE INSPECTION • • • • Please fully inspect unit for damage before installation. If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or replacement. If the unit is damaged by the customer, repair or replacement is the responsibility of the customer. If the unit is damaged by the installer (if other than the customer), repair of replacement must be made by arrangement between customer and installer.
MOUNTING HEIGHTS AND CLEARANCE WARNING • The hood should be installed at 28” minimum above the cooking surface. If pairing your range hood with a gas stove minimum mounting height must be 30” above the cooking surface. Minimum mount height between range top to hood bottom should be no less than 28” for electric or ceramic stoves, and no less than 30” for gas stoves. The maximum mount height should be no more than 36”. The hood must be installed at the correct mounting height.
Ducting Connection When there is no access to the top of the hood, carefully pull down the metal duct through the custom hood base hole. Slide this duct over the adapter/damper. Make sure the adapter/damper assembly enters the ducting. Seal the connection with aluminum tape. TOOLS AND MATERIALS REQUIRED • • • • • • Electrical drill or ratchet driver Phillips screwdriver #2 or driver bit Straight blade screwdriver Wire stripper or cutter Tape measure Electrical supplies for wiring (i.e.
SS130 - PARTS SUPPLIED 1 × Hood 1 × Round Adapter 1 × Rectangular Oil Collector 1 × Plastic Adapter Seal HARDWARE PACKAGE 6 × Adapter Screws 8 Cyclone Insert Installation - English PRE-INSTALLED 2 × LED Lights (1.5W per bulb) *Bulb & socket may change.
SS130 INSERT HOOD INSTALLATION This appliance requires 120V 60Hz electrical supply and connection to an individual properly grounded branch circuit protected by a circuit breaker or time delay fuse. CAUTION • • 1. 2. 3. At least two installers are required due to the weight and size of the hood. WARNING • Install the SS130 Range Hood 4. Turn off power circuit at the service panel before wiring this unit.
SS130 - INSTALLATION CUTOUT TEMPLATES SS13024 SS13030 10 Cyclone Insert Installation - English
BX155/BX212/BX215 - PARTS SUPPLIED 1 × Hood BX212/BX212 INCLUDED IN UNIT 2 × Halogen Lights (120V, 25W per bulb) 1 × Hood BX155 1 × Round Adapter (BX212/BX215 only) 1 × Rectangular Oil Collector (BX212/BX215 only) 1 × Plastic Adapter Seal (BX212/BX215 only) HARDWARE PACKAGE 4 × Mounting Screws 6 × Adapter Screws (BX212/BX215 only) Cyclone Insert Installation - English 11
BX212/BX215 INSERT HOOD INSTALLATION This appliance requires 120V 60Hz electrical supply and connection to an individual properly grounded branch circuit protected by a circuit breaker or time delay fuse. CAUTION • At least two installers are required due to the weight and size of the hood. Installing the BX212/BX215 Range Hood 1. 2. Remove outer mesh filters of range hood. Attach rubber seal and damper to rectangular cutout on top of the range hood using the screws provided (Figure 2). Figure 2.
BX155 INSERT HOOD INSTALLATION This appliance requires 120V 60Hz electrical supply and connection to an individual properly grounded branch circuit protected by a circuit breaker or time delay fuse. CAUTION • • At least two installers are required due to the weight and size of the hood. Prior to installing the product, Cyclone recommends inspecting the hood for damage and testing the hood to ensure proper function. Installing the BX155 Range Hood Once the cutout has been made to the insert: 1. 2.
BX155 INSTALLATION - INSTALLATION CUTOUT TEMPLATES BX155/BX212/BX215 - INSTALLATION CUTOUT TEMPLATES BX15522 10 ⅞” BX15522/BX21222 20 ⅞” BX21228/BX21528 10 ⅝” 26 ½” BX21234/BX21534 19 13 ⅛” 13 ½” 32” 14 Cyclone Insert Installation - English
BX600/BX360/CLX60 - PARTS SUPPLIED 1 × Hood PRE-INSTALLED 2 × LED Lights (1.5W per bulb) 1 × Round Adapter 1 × Rectangular Oil Collector HARDWARE PACKAGE 8 × Mounting Screws WARNING • Cutout specs may change without notice. Please refer to www.cyclonerangehoods.
BX600/BX360/CLX60 INSERT HOOD INSTALLATION This appliance requires 120V 60Hz electrical supply and connection to an individual properly grounded branch circuit protected by a circuit breaker or time delay fuse. CAUTION • At least two installers are required due to the weight and size of the hood. Install the BX600/BX360/CLX60 Range Hood 1. 2. Remove both filters by pulling the lever to release the locking mechanism (Figure 1).
BX600/BX360/CLX60 - INSTALLATION CUTOUT TEMPLATES WARNING • Cutout specs may change without notice. Please refer to www.cyclonerangehoods.
INSERT HOODS SPECIFICATIONS BX155 BX212/BX215 BX600/CLX60 BX360 SS13024/SS13030 SIZE 22” BX215 - 28”/34” BX212 - 22"/28"/34” 28”/34” 28”/34” 24”/30” MAX. CUBIC FEET/METER (CFM) 300 BX212 - 300 BX215 - 550 600 300 300 MAX.
TROUBLESHOOTING ISSUE CAUSE Unit doesn’t work after 1. installation. 1. Ensure power is ON for the circuit breaker and unit. 2. The power line and the cable locking connector 2. are not connected properly. Check the power connection with the unit is connected properly. 3. The unit does not turn on when it is at full extension (SS130 only). 3. Check if the slide control is turned off or set to 0. Light indicates power 1. ON but motor doesn’t turn. 2. The motor is defective, possibly seized. 1.
MAINTENANCE For a complete description of our maintenance and operating instructions you may visit us online at www.CycloneRangeHoods.com to download your model’s Use and Care Guide. Due to the fact that we are always striving to improve our products and take advantage of advances in technology there may be slight variations in your product. WARNING • • Always switch off power and unplug before cleaning and maintenance. Mesh filters may discolour over time.
CONTROL PANEL Model: BX212/BX215 The unit is controlled by slide controls. The fan and light are each controlled by a slide control. The fan switch has four positions: HIGH, MED, LOW and OFF. The light switch has two positions, ON and OFF. Model: SS130 The unit is controlled by slide controls. The fan and light are each controlled by a slide control. The fan switch has four positions: HIGH, MED, LOW and OFF. The light switch has two positions, ON and OFF.
CYCLONE RANGE HOODS LIMITED WARRANTY Cyclone Range Hoods Inc. (Hereunder called “The Company”) provides a warranty that its products are free from defects in workmanship and materials for a period of two (2) years from the date of purchase. This warranty includes in-home service (where applicable) for the first year and workshop service for the second year. During that time period, The Company will, at the Company’s option, repair or replace without charge any parts or complete unit found to be defective.